Evaluación de los niveles de iluminación y su incidencia en la capacidad visual de los trabajadores de las áreas de tornos convencionales y tornos CNC de la empresa Servisilva Cia ltda. Ubicada en la ciudad de puerto francisco de Orellana periodo 2016. Propuesta de mejora de iluminación.

The purpose of this research work arise of the necessity to maintain a uniform lighting environment in the lathe area for non-compliance with 5CT by clause 10.14.1. The American Petroleum Institute (API), which establishes at least 500 lux. and also the Ecuadorian health and safety regulations throu...

Deskribapen osoa

Gorde:
Xehetasun bibliografikoak
Egile nagusia: Montes Vega, Klever Saúl (author)
Formatua: masterThesis
Hizkuntza:spa
Argitaratua: 2017
Gaiak:
Sarrera elektronikoa:http://repositorio.utc.edu.ec/handle/27000/6290
Etiketak: Etiketa erantsi
Etiketarik gabe, Izan zaitez lehena erregistro honi etiketa jartzen!
_version_ 1822282032368058368
author Montes Vega, Klever Saúl
author_facet Montes Vega, Klever Saúl
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv Espín Beltrán, Cristian Xavier, Msc.
dc.creator.none.fl_str_mv Montes Vega, Klever Saúl
dc.date.none.fl_str_mv 2017-01
2020-08-31T01:53:48Z
2020-08-31T01:53:48Z
dc.format.none.fl_str_mv 176 páginas
dc.identifier.none.fl_str_mv Montes Vega Klever Saúl (2017); Evaluación de los niveles de iluminación y su incidencia en la capacidad visual de los trabajadores de las áreas de tornos convencionales y tornos CNC de la empresa Servisilva Cia ltda. Ubicada en la ciudad de puerto francisco de Orellana periodo 2016. Propuesta de mejora de iluminación. UTC. Latacunga. 176 p.
MUTC-000497
http://repositorio.utc.edu.ec/handle/27000/6290
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC).
dc.rights.none.fl_str_mv closedAccess
http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv LUMINACIÓN
INCIDENCIA
CAPACIDAD
GESTIÓN ADMINISTRATIVA
dc.title.none.fl_str_mv Evaluación de los niveles de iluminación y su incidencia en la capacidad visual de los trabajadores de las áreas de tornos convencionales y tornos CNC de la empresa Servisilva Cia ltda. Ubicada en la ciudad de puerto francisco de Orellana periodo 2016. Propuesta de mejora de iluminación.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/masterThesis
description The purpose of this research work arise of the necessity to maintain a uniform lighting environment in the lathe area for non-compliance with 5CT by clause 10.14.1. The American Petroleum Institute (API), which establishes at least 500 lux. and also the Ecuadorian health and safety regulations through executive decree 2393 art 56 To maintain the visual health care of workers. the research objective is evaluate the lighting level which did do made a direct measurement in the conventional lathes area and CNC lathes area which the lighting levels are less to 500 lux. this can cause different effects on the product and the workers health. In the analysis some research techniques were used such as: the interview and the direct measuring to obtain the data in order to evaluate and compare them according with the applicable standards. In conclusion the lightning not is enough for the activity that realize and is recommended to apply the recommended proposal to maintain a uniform lighting environment workstation The proposal was carried out through Lumenes method which help us to calculate the numbers of necessary luminaries depending on the area´s size, the height of the work plane, and the height where the luminaires are suspended. The lightings were chosen by means of a cost benefit analysis, maintaining a level of saving electrical and investment where the best option was chosen within a variety of analyzed luminaries.
eu_rights_str_mv openAccess
format masterThesis
id UTC_a99f51ef41e4d460d4f895efcd785d2a
identifier_str_mv Montes Vega Klever Saúl (2017); Evaluación de los niveles de iluminación y su incidencia en la capacidad visual de los trabajadores de las áreas de tornos convencionales y tornos CNC de la empresa Servisilva Cia ltda. Ubicada en la ciudad de puerto francisco de Orellana periodo 2016. Propuesta de mejora de iluminación. UTC. Latacunga. 176 p.
MUTC-000497
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:oai:repositorio.utc.edu.ec:27000:27000/6290
publishDate 2017
publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC).
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv closedAccess
http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Evaluación de los niveles de iluminación y su incidencia en la capacidad visual de los trabajadores de las áreas de tornos convencionales y tornos CNC de la empresa Servisilva Cia ltda. Ubicada en la ciudad de puerto francisco de Orellana periodo 2016. Propuesta de mejora de iluminación.Montes Vega, Klever SaúlLUMINACIÓNINCIDENCIACAPACIDADGESTIÓN ADMINISTRATIVAThe purpose of this research work arise of the necessity to maintain a uniform lighting environment in the lathe area for non-compliance with 5CT by clause 10.14.1. The American Petroleum Institute (API), which establishes at least 500 lux. and also the Ecuadorian health and safety regulations through executive decree 2393 art 56 To maintain the visual health care of workers. the research objective is evaluate the lighting level which did do made a direct measurement in the conventional lathes area and CNC lathes area which the lighting levels are less to 500 lux. this can cause different effects on the product and the workers health. In the analysis some research techniques were used such as: the interview and the direct measuring to obtain the data in order to evaluate and compare them according with the applicable standards. In conclusion the lightning not is enough for the activity that realize and is recommended to apply the recommended proposal to maintain a uniform lighting environment workstation The proposal was carried out through Lumenes method which help us to calculate the numbers of necessary luminaries depending on the area´s size, the height of the work plane, and the height where the luminaires are suspended. The lightings were chosen by means of a cost benefit analysis, maintaining a level of saving electrical and investment where the best option was chosen within a variety of analyzed luminaries.La presente investigación surge de la necesidad de mantener un ambiente lumínico uniforme en el área de torno, por el incumplimiento a normativa 5CT mediante clausula 10.14.1. De la normas API (American Petroleum Institute) que determina como mínimo 500 lux. y de igual forma la normativa Ecuatoriana de seguridad y salud mediante decreto ejecutivo 2393 art 56, para mantener el cuidado de la salud visual de los trabajadores El objetivo de la investigación es evaluar el nivel de iluminación para lo cual se realizó una medición directa en las áreas de tornos convencionales y torno CNC en las cuales los niveles de iluminación son menores a 500 lux; esto puede causar diferentes efectos tanto en la elaboración del producto como en la capacidad visual En el análisis se utilizaron técnicas de investigación como entrevista y medición directa para la obtención de datos y poder evaluar y cotejar con las normativas aplicables. En conclusión, la iluminación no es suficiente para la actividad que se realiza y se recomienda aplicar la propuesta recomendada para mantener un ambiente de trabajo uniformemente iluminado La propuesta fue realizada mediante el método de lúmenes el cual nos ayuda a calcular el número de luminarias necesarias dependiendo el tamaño del área, la altura del plano de trabajo y la altura donde se encuentran suspendidas. Las luminarias fueron elegidas mediante un análisis de costo beneficio manteniendo un nivel de ahorro eléctrico e inversión donde se eligió la mejor opción dentro de una variedad de luminarias analizadas.Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC).Espín Beltrán, Cristian Xavier, Msc.2020-08-31T01:53:48Z2020-08-31T01:53:48Z2017-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis176 páginasMontes Vega Klever Saúl (2017); Evaluación de los niveles de iluminación y su incidencia en la capacidad visual de los trabajadores de las áreas de tornos convencionales y tornos CNC de la empresa Servisilva Cia ltda. Ubicada en la ciudad de puerto francisco de Orellana periodo 2016. Propuesta de mejora de iluminación. UTC. Latacunga. 176 p.MUTC-000497http://repositorio.utc.edu.ec/handle/27000/6290spaclosedAccesshttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2020-08-31T08:00:20Zoai:oai:repositorio.utc.edu.ec:27000:27000/6290Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02025-01-26T03:44:27.482879Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle Evaluación de los niveles de iluminación y su incidencia en la capacidad visual de los trabajadores de las áreas de tornos convencionales y tornos CNC de la empresa Servisilva Cia ltda. Ubicada en la ciudad de puerto francisco de Orellana periodo 2016. Propuesta de mejora de iluminación.
Montes Vega, Klever Saúl
LUMINACIÓN
INCIDENCIA
CAPACIDAD
GESTIÓN ADMINISTRATIVA
status_str publishedVersion
title Evaluación de los niveles de iluminación y su incidencia en la capacidad visual de los trabajadores de las áreas de tornos convencionales y tornos CNC de la empresa Servisilva Cia ltda. Ubicada en la ciudad de puerto francisco de Orellana periodo 2016. Propuesta de mejora de iluminación.
title_full Evaluación de los niveles de iluminación y su incidencia en la capacidad visual de los trabajadores de las áreas de tornos convencionales y tornos CNC de la empresa Servisilva Cia ltda. Ubicada en la ciudad de puerto francisco de Orellana periodo 2016. Propuesta de mejora de iluminación.
title_fullStr Evaluación de los niveles de iluminación y su incidencia en la capacidad visual de los trabajadores de las áreas de tornos convencionales y tornos CNC de la empresa Servisilva Cia ltda. Ubicada en la ciudad de puerto francisco de Orellana periodo 2016. Propuesta de mejora de iluminación.
title_full_unstemmed Evaluación de los niveles de iluminación y su incidencia en la capacidad visual de los trabajadores de las áreas de tornos convencionales y tornos CNC de la empresa Servisilva Cia ltda. Ubicada en la ciudad de puerto francisco de Orellana periodo 2016. Propuesta de mejora de iluminación.
title_short Evaluación de los niveles de iluminación y su incidencia en la capacidad visual de los trabajadores de las áreas de tornos convencionales y tornos CNC de la empresa Servisilva Cia ltda. Ubicada en la ciudad de puerto francisco de Orellana periodo 2016. Propuesta de mejora de iluminación.
title_sort Evaluación de los niveles de iluminación y su incidencia en la capacidad visual de los trabajadores de las áreas de tornos convencionales y tornos CNC de la empresa Servisilva Cia ltda. Ubicada en la ciudad de puerto francisco de Orellana periodo 2016. Propuesta de mejora de iluminación.
topic LUMINACIÓN
INCIDENCIA
CAPACIDAD
GESTIÓN ADMINISTRATIVA
url http://repositorio.utc.edu.ec/handle/27000/6290