Análisis del sistema de protección de puesta a tierra y apantallamiento eléctrico en una planta minera.

This research work deals with the analysis of the grounding and electrical shielding protection system in the Agroindustrial El Corazón mining flotation plant. The proposal arises from the need of the electrical department to identify disturbances and verify the correct performance of the grounding...

תיאור מלא

שמור ב:
מידע ביבליוגרפי
מחבר ראשי: Orbea García, Jefferson Marcelo (author)
פורמט: masterThesis
שפה:spa
יצא לאור: 2023
נושאים:
גישה מקוונת:http://repositorio.utc.edu.ec/handle/27000/10936
תגים: הוספת תג
אין תגיות, היה/י הראשונ/ה לתייג את הרשומה!
_version_ 1822282062240940032
author Orbea García, Jefferson Marcelo
author_facet Orbea García, Jefferson Marcelo
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv Salazar, Edgar
dc.creator.none.fl_str_mv Orbea García, Jefferson Marcelo
dc.date.none.fl_str_mv 2023-09-21T17:39:47Z
2023-09-21T17:39:47Z
2023
dc.format.none.fl_str_mv 100 páginas.
dc.identifier.none.fl_str_mv Orbea García , Jefferson Marcelo (2023), Análisis del sistema de protección de puesta a tierra y apantallamiento eléctrico en una planta minera. Latacunga. UTC. 100p.
MUTC-001703
http://repositorio.utc.edu.ec/handle/27000/10936
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi; UTC.
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv SISTEMAS DE PUESTA A TIERRA
MÉTODOS DE ELEMENTOS FINITOS
SOFTWARE ETAP
APANTALLAMIENTO ELÉCTRICO
ELÉCTRICA
dc.title.none.fl_str_mv Análisis del sistema de protección de puesta a tierra y apantallamiento eléctrico en una planta minera.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/masterThesis
description This research work deals with the analysis of the grounding and electrical shielding protection system in the Agroindustrial El Corazón mining flotation plant. The proposal arises from the need of the electrical department to identify disturbances and verify the correct performance of the grounding system (SPT) and the evaluation of the feasibility and design of a protection system against atmospheric discharges. The SPT is studied with measurements of the soil resistivity, the geometry and the resistance of the three meshes. In the ETAP software, a 2-layer soil model is established, the geometries of each mesh are loaded and the finite element technique is applied to obtain the resistance, touch and step voltage of each mesh. The simulation shows that mesh 1 generates a touch voltage of 1823V, exceeding the tolerable limit of 988V according to IEEE-80. Proposals for equipotentialization of the meshes are made and the graphs of the potential gradients are analyzed. With the adaptations, equipotentiality is obtained throughout the installation and a maximum step voltage of 900V and a uniform potential distribution are obtained. Regarding the design of the protection system against atmospheric discharges, the risk level of NPR=1 was determined. For external protection, the electrogeometric method of rolling spheres is used by placing lightning capture spikes in ten locations in the plant, downspouts and goose-foot type ground outlets are determined to drain lightning currents. Regarding internal protection, the study is carried out on the SPDs for medium voltage on the MV side and the SPDs type 1 and 2 combined, Type 2 and Type 3 that are installed in certain low voltage areas.
eu_rights_str_mv openAccess
format masterThesis
id UTC_adb27b3fcffd7c84ff50ecf6721d50ab
identifier_str_mv Orbea García , Jefferson Marcelo (2023), Análisis del sistema de protección de puesta a tierra y apantallamiento eléctrico en una planta minera. Latacunga. UTC. 100p.
MUTC-001703
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:oai:repositorio.utc.edu.ec:27000:27000/10936
publishDate 2023
publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi; UTC.
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Análisis del sistema de protección de puesta a tierra y apantallamiento eléctrico en una planta minera.Orbea García, Jefferson MarceloSISTEMAS DE PUESTA A TIERRAMÉTODOS DE ELEMENTOS FINITOSSOFTWARE ETAPAPANTALLAMIENTO ELÉCTRICOELÉCTRICAThis research work deals with the analysis of the grounding and electrical shielding protection system in the Agroindustrial El Corazón mining flotation plant. The proposal arises from the need of the electrical department to identify disturbances and verify the correct performance of the grounding system (SPT) and the evaluation of the feasibility and design of a protection system against atmospheric discharges. The SPT is studied with measurements of the soil resistivity, the geometry and the resistance of the three meshes. In the ETAP software, a 2-layer soil model is established, the geometries of each mesh are loaded and the finite element technique is applied to obtain the resistance, touch and step voltage of each mesh. The simulation shows that mesh 1 generates a touch voltage of 1823V, exceeding the tolerable limit of 988V according to IEEE-80. Proposals for equipotentialization of the meshes are made and the graphs of the potential gradients are analyzed. With the adaptations, equipotentiality is obtained throughout the installation and a maximum step voltage of 900V and a uniform potential distribution are obtained. Regarding the design of the protection system against atmospheric discharges, the risk level of NPR=1 was determined. For external protection, the electrogeometric method of rolling spheres is used by placing lightning capture spikes in ten locations in the plant, downspouts and goose-foot type ground outlets are determined to drain lightning currents. Regarding internal protection, the study is carried out on the SPDs for medium voltage on the MV side and the SPDs type 1 and 2 combined, Type 2 and Type 3 that are installed in certain low voltage areas.El presente trabajo de investigación trata sobre el análisis del sistema de protección de puesta a tierra y apantallamiento eléctrico en la planta de flotación minera Agroindustrial El Corazón. La propuesta surge ante la necesidad del departamento eléctrico para identificar las perturbaciones y comprobar el correcto rendimiento del sistema de puesta a tierra (SPT) y la evaluación de la factibilidad y diseño un sistema de protección ante descargas atmosféricas. Se estudia el SPT con mediciones de la resistividad del suelo, la geometría y la resistencia de las tres mallas. En el software ETAP, se establece un modelo de suelo de 2 capas, se cargan las geometrías de cada malla y se aplica la técnica de elementos finitos para obtener la resistencia, voltaje de toque y de paso de cada malla. La simulación entrega que la malla 1 genera un voltaje de toque de 1823V superando el límite tolerable de 988V según IEEE-80. Se realiza las propuestas de equipotencialización de las mallas y se analiza las gráficas de los gradientes de potencial. Con las adecuaciones se obtiene una equipotencialidad en toda la instalación y obtiene voltaje de paso máximo de 900V y una distribución de potencial uniforme. Con respecto al diseño del sistema de protección contra descargas atmosféricas, se determinó el nivel de riesgo de NPR=1. Para la protección externa se usa el método electrogeométrico de las esferas rodantes mediante la colocación de puntas captadoras de rayo en diez ubicaciones en la planta, se determina los bajantes y tomas de tierra tipo pata de ganso para drenar corrientes de rayo. De la protección interna se realiza el estudio de los DPS para media tensión en el lado MT y los DPS tipo 1 y 2 combinado, Tipo 2 y Tipo 3 que se instalan en las zonas determinadas de baja tensión.Ecuador: Latacunga: Universidad Técnica de Cotopaxi; UTC.Salazar, Edgar2023-09-21T17:39:47Z2023-09-21T17:39:47Z2023info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis100 páginas.Orbea García , Jefferson Marcelo (2023), Análisis del sistema de protección de puesta a tierra y apantallamiento eléctrico en una planta minera. Latacunga. UTC. 100p.MUTC-001703http://repositorio.utc.edu.ec/handle/27000/10936spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2023-09-22T08:00:32Zoai:oai:repositorio.utc.edu.ec:27000:27000/10936Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02025-01-26T03:45:55.070200Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle Análisis del sistema de protección de puesta a tierra y apantallamiento eléctrico en una planta minera.
Orbea García, Jefferson Marcelo
SISTEMAS DE PUESTA A TIERRA
MÉTODOS DE ELEMENTOS FINITOS
SOFTWARE ETAP
APANTALLAMIENTO ELÉCTRICO
ELÉCTRICA
status_str publishedVersion
title Análisis del sistema de protección de puesta a tierra y apantallamiento eléctrico en una planta minera.
title_full Análisis del sistema de protección de puesta a tierra y apantallamiento eléctrico en una planta minera.
title_fullStr Análisis del sistema de protección de puesta a tierra y apantallamiento eléctrico en una planta minera.
title_full_unstemmed Análisis del sistema de protección de puesta a tierra y apantallamiento eléctrico en una planta minera.
title_short Análisis del sistema de protección de puesta a tierra y apantallamiento eléctrico en una planta minera.
title_sort Análisis del sistema de protección de puesta a tierra y apantallamiento eléctrico en una planta minera.
topic SISTEMAS DE PUESTA A TIERRA
MÉTODOS DE ELEMENTOS FINITOS
SOFTWARE ETAP
APANTALLAMIENTO ELÉCTRICO
ELÉCTRICA
url http://repositorio.utc.edu.ec/handle/27000/10936