El dimensionamiento geométrico y su incidencia en la eficiencia energética de la turbina pelton de las unidades tres y cuatro, en la central de generación hidroeléctrica Illuchi i, de la empresa Elepco S.A. elaboración de una base informática de respaldo de ingeniería Cad – Cam.

The present project seeks to obtain maximum efficiency in the Pelton turbine of units three and four of the hydroelectric generation plant Illuchi I in the company ELEPCO S.A., by the appropriate geometric dimensioning in function of the characteristics of the water source. Deficiencies in manufactu...

Ful tanımlama

Kaydedildi:
Detaylı Bibliyografya
Yazar: Toro Rubio, Jaime Patricio (author)
Materyal Türü: masterThesis
Dil:spa
Baskı/Yayın Bilgisi: 2017
Konular:
Online Erişim:http://repositorio.utc.edu.ec/handle/27000/6573
Etiketler: Etiketle
Etiket eklenmemiş, İlk siz ekleyin!
_version_ 1862869193916940288
author Toro Rubio, Jaime Patricio
author_facet Toro Rubio, Jaime Patricio
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv Torres Tamayo, Enrique, PhD.
dc.creator.none.fl_str_mv Toro Rubio, Jaime Patricio
dc.date.none.fl_str_mv 2017-02
2020-10-21T00:33:07Z
2020-10-21T00:33:07Z
dc.format.none.fl_str_mv 150 páginas
application/pdf
dc.identifier.none.fl_str_mv Toro Rubio, Jaime Patricio (2017); El dimensionamiento geométrico y su incidencia en la eficiencia energética de la turbina pelton de las unidades tres y cuatro, en la central de generación hidroeléctrica Illuchi i, de la empresa Elepco S.A. elaboración de una base informática de respaldo de ingeniería Cad – Cam. UTC. Latacunga. 150 p.
MUTC-000503
http://repositorio.utc.edu.ec/handle/27000/6573
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC).
dc.rights.none.fl_str_mv closedAccess
http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv DIMENSIONAMIENTO GEOMÉTRICO
EFICIENCIA ENERGÉTICA
TURBINA PELTON
INGENIERIA CAD – CAM
GESTIÓN ADMINISTRATIVA
dc.title.none.fl_str_mv El dimensionamiento geométrico y su incidencia en la eficiencia energética de la turbina pelton de las unidades tres y cuatro, en la central de generación hidroeléctrica Illuchi i, de la empresa Elepco S.A. elaboración de una base informática de respaldo de ingeniería Cad – Cam.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/masterThesis
description The present project seeks to obtain maximum efficiency in the Pelton turbine of units three and four of the hydroelectric generation plant Illuchi I in the company ELEPCO S.A., by the appropriate geometric dimensioning in function of the characteristics of the water source. Deficiencies in manufacturing methods and engineering data loss have been identified, resulting in a loss of efficiency system and reduced reliability in the operation of the equipment. It made the simulation of the behavior of the blade in contact with the fluid through of design software, besides; the hydrodynamics with respect to the water circulation by the surface of the piece, to obtain the greater efficiency and decrease the lost characteristics produced by the system. This model besought is based on the identification, evaluation and characterization of the operational parameters, and the reference measurements of the Pelton turbine were determined to be evaluated by simulation software using the finite element method and to obtain an increase in the Power of 230.92 kW per generation unit, resulting in an annual return of US $ 159611.90 and with a price of US $ 0.04 per kWh. In this way the objective of an efficient energy system based on the correct geometric dimensioning, supported by the development of a CAD - CAM digital computer base, is fulfilled.
eu_rights_str_mv openAccess
format masterThesis
id UTC_c086ae80bbd8a4b05ee1582880c944e9
identifier_str_mv Toro Rubio, Jaime Patricio (2017); El dimensionamiento geométrico y su incidencia en la eficiencia energética de la turbina pelton de las unidades tres y cuatro, en la central de generación hidroeléctrica Illuchi i, de la empresa Elepco S.A. elaboración de una base informática de respaldo de ingeniería Cad – Cam. UTC. Latacunga. 150 p.
MUTC-000503
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:repositorio.utc.edu.ec:27000/6573
publishDate 2017
publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC).
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv closedAccess
http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling El dimensionamiento geométrico y su incidencia en la eficiencia energética de la turbina pelton de las unidades tres y cuatro, en la central de generación hidroeléctrica Illuchi i, de la empresa Elepco S.A. elaboración de una base informática de respaldo de ingeniería Cad – Cam.Toro Rubio, Jaime PatricioDIMENSIONAMIENTO GEOMÉTRICOEFICIENCIA ENERGÉTICATURBINA PELTONINGENIERIA CAD – CAMGESTIÓN ADMINISTRATIVAThe present project seeks to obtain maximum efficiency in the Pelton turbine of units three and four of the hydroelectric generation plant Illuchi I in the company ELEPCO S.A., by the appropriate geometric dimensioning in function of the characteristics of the water source. Deficiencies in manufacturing methods and engineering data loss have been identified, resulting in a loss of efficiency system and reduced reliability in the operation of the equipment. It made the simulation of the behavior of the blade in contact with the fluid through of design software, besides; the hydrodynamics with respect to the water circulation by the surface of the piece, to obtain the greater efficiency and decrease the lost characteristics produced by the system. This model besought is based on the identification, evaluation and characterization of the operational parameters, and the reference measurements of the Pelton turbine were determined to be evaluated by simulation software using the finite element method and to obtain an increase in the Power of 230.92 kW per generation unit, resulting in an annual return of US $ 159611.90 and with a price of US $ 0.04 per kWh. In this way the objective of an efficient energy system based on the correct geometric dimensioning, supported by the development of a CAD - CAM digital computer base, is fulfilled.El presente proyecto busca obtener la máxima eficiencia en la turbina Pelton de las unidades tres y cuatro de la central de generación hidroeléctrica Illuchi I en la empresa ELEPCO S.A., mediante el adecuado dimensionamiento geométrico en función de las características de la fuente hídrica. Se ha identificado deficiencias en los métodos de manufacturación y merma de datos ingenieriles, lo que ocasiona perdida de eficiencia en el sistema y reduce la confiabilidad en operación del equipo. Se realizó la simulación del comportamiento del álabe en contacto con el fluido por medio de un software de diseño, además; la hidrodinámica del mismo con respecto a la circulación del agua por la superficie de la pieza, para obtener la mayor eficiencia posible y disminuir las perdidas características producidas por el sistema. Con el modelo propuesto con base en la identificación, evaluación y caracterización de los parámetros operacionales, se determinó las medidas referenciales de la turbina Pelton para luego ser evaluadas mediante un software de simulación por medio del método de elementos finitos y obtener un incremento en la potencia de 230.92 kW por unidad de generación, lo que resulta con una rentabilidad anual de $ 159611,90 dólares americanos y con un precio de $ 0,04 dólares americanos por kWh. De esta manera se cumple con el objetivo planteado de un sistema energético eficiente basado en el correcto dimensionamiento geométrico, respaldado por la elaboración de una base informática digital CAD – CAM.Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC).Torres Tamayo, Enrique, PhD.2020-10-21T00:33:07Z2020-10-21T00:33:07Z2017-02info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis150 páginasapplication/pdfToro Rubio, Jaime Patricio (2017); El dimensionamiento geométrico y su incidencia en la eficiencia energética de la turbina pelton de las unidades tres y cuatro, en la central de generación hidroeléctrica Illuchi i, de la empresa Elepco S.A. elaboración de una base informática de respaldo de ingeniería Cad – Cam. UTC. Latacunga. 150 p.MUTC-000503http://repositorio.utc.edu.ec/handle/27000/6573spaclosedAccesshttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2020-10-21T08:01:04Zoai:repositorio.utc.edu.ec:27000/6573Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02026-04-19T03:41:28.999947Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle El dimensionamiento geométrico y su incidencia en la eficiencia energética de la turbina pelton de las unidades tres y cuatro, en la central de generación hidroeléctrica Illuchi i, de la empresa Elepco S.A. elaboración de una base informática de respaldo de ingeniería Cad – Cam.
Toro Rubio, Jaime Patricio
DIMENSIONAMIENTO GEOMÉTRICO
EFICIENCIA ENERGÉTICA
TURBINA PELTON
INGENIERIA CAD – CAM
GESTIÓN ADMINISTRATIVA
status_str publishedVersion
title El dimensionamiento geométrico y su incidencia en la eficiencia energética de la turbina pelton de las unidades tres y cuatro, en la central de generación hidroeléctrica Illuchi i, de la empresa Elepco S.A. elaboración de una base informática de respaldo de ingeniería Cad – Cam.
title_full El dimensionamiento geométrico y su incidencia en la eficiencia energética de la turbina pelton de las unidades tres y cuatro, en la central de generación hidroeléctrica Illuchi i, de la empresa Elepco S.A. elaboración de una base informática de respaldo de ingeniería Cad – Cam.
title_fullStr El dimensionamiento geométrico y su incidencia en la eficiencia energética de la turbina pelton de las unidades tres y cuatro, en la central de generación hidroeléctrica Illuchi i, de la empresa Elepco S.A. elaboración de una base informática de respaldo de ingeniería Cad – Cam.
title_full_unstemmed El dimensionamiento geométrico y su incidencia en la eficiencia energética de la turbina pelton de las unidades tres y cuatro, en la central de generación hidroeléctrica Illuchi i, de la empresa Elepco S.A. elaboración de una base informática de respaldo de ingeniería Cad – Cam.
title_short El dimensionamiento geométrico y su incidencia en la eficiencia energética de la turbina pelton de las unidades tres y cuatro, en la central de generación hidroeléctrica Illuchi i, de la empresa Elepco S.A. elaboración de una base informática de respaldo de ingeniería Cad – Cam.
title_sort El dimensionamiento geométrico y su incidencia en la eficiencia energética de la turbina pelton de las unidades tres y cuatro, en la central de generación hidroeléctrica Illuchi i, de la empresa Elepco S.A. elaboración de una base informática de respaldo de ingeniería Cad – Cam.
topic DIMENSIONAMIENTO GEOMÉTRICO
EFICIENCIA ENERGÉTICA
TURBINA PELTON
INGENIERIA CAD – CAM
GESTIÓN ADMINISTRATIVA
url http://repositorio.utc.edu.ec/handle/27000/6573