Estudio de la calidad de energía eléctrica en la Corporación Ecuatoriana de Aluminio Cedal S.A. ubicada en la ciudad de Latacunga en el año 2021.
The present study was carried out at Corporación Ecuatoriana de Aluminio CEDAL S.A., an industry located in the city of Latacunga and dedicated to the manufacture and commercialization of aluminum extrusions at national and international level. The intention of this project is to analyze the power q...
Saved in:
| Main Author: | |
|---|---|
| Other Authors: | |
| Format: | bachelorThesis |
| Language: | spa |
| Published: |
2021
|
| Subjects: | |
| Online Access: | http://repositorio.utc.edu.ec/handle/27000/7951 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1822282044101623808 |
|---|---|
| author | Antamba Valenzuela, Bryan Fernando |
| author2 | Gómez Calvopiña, Angel Francisco |
| author2_role | author |
| author_facet | Antamba Valenzuela, Bryan Fernando Gómez Calvopiña, Angel Francisco |
| author_role | author |
| collection | Repositorio Universidad Técnica de Cotopaxi |
| dc.contributor.none.fl_str_mv | Salazar, Edgar |
| dc.creator.none.fl_str_mv | Antamba Valenzuela, Bryan Fernando Gómez Calvopiña, Angel Francisco |
| dc.date.none.fl_str_mv | 2021-07 2022-01-11T19:32:28Z 2022-01-11T19:32:28Z |
| dc.format.none.fl_str_mv | 127 páginas |
| dc.identifier.none.fl_str_mv | Antamba Valenzuela Bryan Fernando, Gómez Calvopiña Angel Francisco, (2021), Estudio de la calidad de energía eléctrica en la Corporación Ecuatoriana de Aluminio Cedal S.A. ubicada en la ciudad de Latacunga en el año 2021. UTC. Latacunga. 127 p. PI-001728 http://repositorio.utc.edu.ec/handle/27000/7951 |
| dc.language.none.fl_str_mv | spa |
| dc.publisher.none.fl_str_mv | Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC. |
| dc.rights.none.fl_str_mv | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ info:eu-repo/semantics/openAccess |
| dc.source.none.fl_str_mv | reponame:Repositorio Universidad Técnica de Cotopaxi instname:Universidad Técnica de Cotopaxi instacron:UTC |
| dc.subject.none.fl_str_mv | PERTURBACIONES ELÉCTRICAS ARMÓNICOS FACTOR DE POTENCIA CALIDAD DE ENERGÍA INGENIERÍA ELÉCTRICA |
| dc.title.none.fl_str_mv | Estudio de la calidad de energía eléctrica en la Corporación Ecuatoriana de Aluminio Cedal S.A. ubicada en la ciudad de Latacunga en el año 2021. |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/bachelorThesis |
| description | The present study was carried out at Corporación Ecuatoriana de Aluminio CEDAL S.A., an industry located in the city of Latacunga and dedicated to the manufacture and commercialization of aluminum extrusions at national and international level. The intention of this project is to analyze the power quality in the power supply system in the extrusion area of the plant, through national and international standards such as CONELEC 005/18, ARCERNNR 200/20 and IEEE std 519, IEEE std 1159. This study includes a bibliographic and field review, which provided significant knowledge for the development of the proposed topic. Data on electrical parameters in the three transformers present in the extrusion area were recorded with a FLUKE 435- SII network analyzer, in addition to this, the load survey and updating of single-line diagrams of the electrical system were elaborated, which were subsequently used in the simulations performed in the EASY POWER program through which the most significant disturbances of the system such as low power factor and voltage and current harmonics could be analyzed. These problems are relevant in the economy of an industry because they cause damage to machinery, electrical elements, and an excessive payment in energy consumption. Harmonic mitigation methods have been proposed based on the analysis of the data obtained through the analyzer and simulations, showing the feasibility and benefits of the project, both economic and technical. |
| eu_rights_str_mv | openAccess |
| format | bachelorThesis |
| id | UTC_c7bfb9d64dd67c73d026096aa0a1072b |
| identifier_str_mv | Antamba Valenzuela Bryan Fernando, Gómez Calvopiña Angel Francisco, (2021), Estudio de la calidad de energía eléctrica en la Corporación Ecuatoriana de Aluminio Cedal S.A. ubicada en la ciudad de Latacunga en el año 2021. UTC. Latacunga. 127 p. PI-001728 |
| instacron_str | UTC |
| institution | UTC |
| instname_str | Universidad Técnica de Cotopaxi |
| language | spa |
| network_acronym_str | UTC |
| network_name_str | Repositorio Universidad Técnica de Cotopaxi |
| oai_identifier_str | oai:oai:repositorio.utc.edu.ec:27000:27000/7951 |
| publishDate | 2021 |
| publisher.none.fl_str_mv | Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC. |
| reponame_str | Repositorio Universidad Técnica de Cotopaxi |
| repository.mail.fl_str_mv | . |
| repository.name.fl_str_mv | Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi |
| repository_id_str | 0 |
| rights_invalid_str_mv | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ |
| spelling | Estudio de la calidad de energía eléctrica en la Corporación Ecuatoriana de Aluminio Cedal S.A. ubicada en la ciudad de Latacunga en el año 2021.Antamba Valenzuela, Bryan FernandoGómez Calvopiña, Angel FranciscoPERTURBACIONES ELÉCTRICASARMÓNICOSFACTOR DE POTENCIACALIDAD DE ENERGÍAINGENIERÍA ELÉCTRICAThe present study was carried out at Corporación Ecuatoriana de Aluminio CEDAL S.A., an industry located in the city of Latacunga and dedicated to the manufacture and commercialization of aluminum extrusions at national and international level. The intention of this project is to analyze the power quality in the power supply system in the extrusion area of the plant, through national and international standards such as CONELEC 005/18, ARCERNNR 200/20 and IEEE std 519, IEEE std 1159. This study includes a bibliographic and field review, which provided significant knowledge for the development of the proposed topic. Data on electrical parameters in the three transformers present in the extrusion area were recorded with a FLUKE 435- SII network analyzer, in addition to this, the load survey and updating of single-line diagrams of the electrical system were elaborated, which were subsequently used in the simulations performed in the EASY POWER program through which the most significant disturbances of the system such as low power factor and voltage and current harmonics could be analyzed. These problems are relevant in the economy of an industry because they cause damage to machinery, electrical elements, and an excessive payment in energy consumption. Harmonic mitigation methods have been proposed based on the analysis of the data obtained through the analyzer and simulations, showing the feasibility and benefits of the project, both economic and technical.El presente estudio fue realizado en la Corporación Ecuatoriana de Aluminio CEDAL S.A. industria ubicada en la ciudad de Latacunga y dedicada a la fabricación y comercialización de extrusiones de aluminio a nivel nacional e internacional. La intención de este proyecto es analizar la calidad de energía en el sistema de suministro eléctrico en el área de extrusión de la planta, mediante normativas nacionales e internacionales tales como la CONELEC 005/18, ARCERNNR 200/20 e IEEE std 519, IEEE std 1159. Este estudio cuenta con una revisión bibliográfica y de campo, que aporto un conocimiento significativo para el desarrollo del tema propuesto. Se registraron datos sobre parámetros eléctricos en los tres transformadores presentes en el área de extrusión con un analizador de redes FLUKE 435- SII, adicional a esto se elaboró el levantamiento de cargas y actualización de diagramas unifilares del sistema eléctrico, mismos que fueron utilizados posteriormente en las simulaciones realizadas en el programa EASY POWER a través del cual se pudo analizar las perturbaciones más significativas del sistema como son el bajo factor de potencia y los armónicos de voltaje y corriente. Problemáticas que son relevantes en la economía de una industria debido a que producen daño en maquinarias, elementos eléctricos y un pago excesivo en el consumo energético. Se han planteado métodos de mitigación de armónicos basados en el análisis de los datos obtenidos mediante el analizador y las simulaciones, mostrando la factibilidad y benéficos que presenta el proyecto, tanto económicos como técnicos.Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC.Salazar, Edgar2022-01-11T19:32:28Z2022-01-11T19:32:28Z2021-07info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis127 páginasAntamba Valenzuela Bryan Fernando, Gómez Calvopiña Angel Francisco, (2021), Estudio de la calidad de energía eléctrica en la Corporación Ecuatoriana de Aluminio Cedal S.A. ubicada en la ciudad de Latacunga en el año 2021. UTC. Latacunga. 127 p.PI-001728http://repositorio.utc.edu.ec/handle/27000/7951spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2022-01-12T08:00:24Zoai:oai:repositorio.utc.edu.ec:27000:27000/7951Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02025-01-26T03:44:58.849615Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue |
| spellingShingle | Estudio de la calidad de energía eléctrica en la Corporación Ecuatoriana de Aluminio Cedal S.A. ubicada en la ciudad de Latacunga en el año 2021. Antamba Valenzuela, Bryan Fernando PERTURBACIONES ELÉCTRICAS ARMÓNICOS FACTOR DE POTENCIA CALIDAD DE ENERGÍA INGENIERÍA ELÉCTRICA |
| status_str | publishedVersion |
| title | Estudio de la calidad de energía eléctrica en la Corporación Ecuatoriana de Aluminio Cedal S.A. ubicada en la ciudad de Latacunga en el año 2021. |
| title_full | Estudio de la calidad de energía eléctrica en la Corporación Ecuatoriana de Aluminio Cedal S.A. ubicada en la ciudad de Latacunga en el año 2021. |
| title_fullStr | Estudio de la calidad de energía eléctrica en la Corporación Ecuatoriana de Aluminio Cedal S.A. ubicada en la ciudad de Latacunga en el año 2021. |
| title_full_unstemmed | Estudio de la calidad de energía eléctrica en la Corporación Ecuatoriana de Aluminio Cedal S.A. ubicada en la ciudad de Latacunga en el año 2021. |
| title_short | Estudio de la calidad de energía eléctrica en la Corporación Ecuatoriana de Aluminio Cedal S.A. ubicada en la ciudad de Latacunga en el año 2021. |
| title_sort | Estudio de la calidad de energía eléctrica en la Corporación Ecuatoriana de Aluminio Cedal S.A. ubicada en la ciudad de Latacunga en el año 2021. |
| topic | PERTURBACIONES ELÉCTRICAS ARMÓNICOS FACTOR DE POTENCIA CALIDAD DE ENERGÍA INGENIERÍA ELÉCTRICA |
| url | http://repositorio.utc.edu.ec/handle/27000/7951 |