Diseño de un banco experimental de bombeo para el análisis de altura neta positiva de succión en bombas centrífugas

The current research work had as aim to implement an experimental bench for the net positive suction head analysis in centrifugal pumps, this project was based on the scientific method starting with the research on pumping systems and the variables, what influence system pumping, the variables measu...

Бүрэн тодорхойлолт

-д хадгалсан:
Номзүйн дэлгэрэнгүй
Үндсэн зохиолч: Lema Jami, Byron Oswaldo (author)
Бусад зохиолчид: Masaquiza Guaitoso, Christian Manuel (author)
Формат: bachelorThesis
Хэл сонгох:spa
Хэвлэсэн: 2022
Нөхцлүүд:
Онлайн хандалт:http://repositorio.utc.edu.ec/handle/27000/9692
Шошгууд: Шошго нэмэх
Шошго байхгүй, Энэхүү баримтыг шошголох эхний хүн болох!
_version_ 1859064054203547648
author Lema Jami, Byron Oswaldo
author2 Masaquiza Guaitoso, Christian Manuel
author2_role author
author_facet Lema Jami, Byron Oswaldo
Masaquiza Guaitoso, Christian Manuel
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv Laurencio Alfonso, Héctor Luis
dc.creator.none.fl_str_mv Lema Jami, Byron Oswaldo
Masaquiza Guaitoso, Christian Manuel
dc.date.none.fl_str_mv 2022
2023-02-22T17:04:58Z
2023-02-22T17:04:58Z
dc.format.none.fl_str_mv 117 páginas
application/pdf
dc.identifier.none.fl_str_mv Lema Jami Byron Oswaldo, Masaquiza Guaitoso Christian Manuel (2022); Diseño de un banco experimental de bombeo para el análisis de altura neta positiva de succión en bombas centrífugas. UTC. Latacunga. 117 p.
PI-002199
http://repositorio.utc.edu.ec/handle/27000/9692
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC)
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv BOMBAS CENTRÍFUGAS
CAUDAL
NPSH
CAVITACIÓN
ELECTROMECÁNICA
dc.title.none.fl_str_mv Diseño de un banco experimental de bombeo para el análisis de altura neta positiva de succión en bombas centrífugas
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description The current research work had as aim to implement an experimental bench for the net positive suction head analysis in centrifugal pumps, this project was based on the scientific method starting with the research on pumping systems and the variables, what influence system pumping, the variables measurement was performed by means a thermometer and pressure and flow sensors to get precise data, and later, with the PLC LOGO Siemens conditioning and the programming in an instrumentation software, the acquisition and data visualization. The tests were performed at different revolutions by means frequency variation and with the acquired data of flow rate, discharge pressure and vacuum pressure, the graphs H (m) vs Q (m3/h) and NPSH (m) vs Q (m3/h). These graphs determine, what the pump catalog characteristics curves do not coincide with the got experimental data, since according to the equipment plate, the maximum pumping head is 20.5 m, but in the experimentation is reached a maximum flow 15 m3/h at 60 Hz and a maximum head of 15 m at 60 Hz, 11 m at 50 Hz and 7 m at 40 Hz were reached. The available NPSH experimentation was made with the valve´s manipulation located in the suction and in the discharge, which have the purpose of forcing the cavitation in the pump and it was got the graphs at 60 Hz, 50 Hz and 40 Hz what are related to the required NPSH from the catalog curve.
eu_rights_str_mv openAccess
format bachelorThesis
id UTC_ca7903e5e01b0f1db0bfb2630180b656
identifier_str_mv Lema Jami Byron Oswaldo, Masaquiza Guaitoso Christian Manuel (2022); Diseño de un banco experimental de bombeo para el análisis de altura neta positiva de succión en bombas centrífugas. UTC. Latacunga. 117 p.
PI-002199
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:repositorio.utc.edu.ec:27000/9692
publishDate 2022
publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC)
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Diseño de un banco experimental de bombeo para el análisis de altura neta positiva de succión en bombas centrífugasLema Jami, Byron OswaldoMasaquiza Guaitoso, Christian ManuelBOMBAS CENTRÍFUGASCAUDALNPSHCAVITACIÓNELECTROMECÁNICAThe current research work had as aim to implement an experimental bench for the net positive suction head analysis in centrifugal pumps, this project was based on the scientific method starting with the research on pumping systems and the variables, what influence system pumping, the variables measurement was performed by means a thermometer and pressure and flow sensors to get precise data, and later, with the PLC LOGO Siemens conditioning and the programming in an instrumentation software, the acquisition and data visualization. The tests were performed at different revolutions by means frequency variation and with the acquired data of flow rate, discharge pressure and vacuum pressure, the graphs H (m) vs Q (m3/h) and NPSH (m) vs Q (m3/h). These graphs determine, what the pump catalog characteristics curves do not coincide with the got experimental data, since according to the equipment plate, the maximum pumping head is 20.5 m, but in the experimentation is reached a maximum flow 15 m3/h at 60 Hz and a maximum head of 15 m at 60 Hz, 11 m at 50 Hz and 7 m at 40 Hz were reached. The available NPSH experimentation was made with the valve´s manipulation located in the suction and in the discharge, which have the purpose of forcing the cavitation in the pump and it was got the graphs at 60 Hz, 50 Hz and 40 Hz what are related to the required NPSH from the catalog curve.El presente trabajo de investigación tuvo el objetivo de implementar un banco experimental para el análisis de altura neta positiva de succión en bombas centrífugas, este proyecto se basó en el método científico partiendo por la investigación acerca de los sistemas de bombeo y las variables que influyen en el sistema, la medición de las variables se realizaron mediante un termómetro y sensores de presión y caudal para obtener datos precisos, y posteriormente, con el acondicionamiento en el PLC LOGO Siemens y la programación en un software de instrumentación se realizó la adquisición y visualización de los datos. Los ensayos se realizaron a distintas revoluciones mediante la variación de frecuencia y con los datos adquiridos de caudal, presión de descarga y presión de vacío se obtuvo las gráficas H (m) vs Q (m3/h) y NPSH (m) vs Q (m3/h). Estas gráficas determinan que, las curvas características del catálogo de la bomba no coinciden con los datos experimentales obtenidos ya que según la placa del equipo la altura máxima de bombeo es de 20,5 m, pero en la experimentación se alcanzó un caudal máximo en 60 Hz de 15 m3/h y una altura máxima de elevación de 15 m en 60 Hz, 11 m en 50 Hz y 7 m en 40 Hz. La experimentación del NPSH disponible se realizó con la manipulación de las válvulas ubicadas en la succión y en la descarga que tienen la finalidad de forzar la cavitación en la bomba y se obtuvo las gráficas a 60 Hz, 50 Hz y 40 Hz que se relacionan con el NPSH requerido de la curva del catálogo.Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC)Laurencio Alfonso, Héctor Luis2023-02-22T17:04:58Z2023-02-22T17:04:58Z2022info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis117 páginasapplication/pdfLema Jami Byron Oswaldo, Masaquiza Guaitoso Christian Manuel (2022); Diseño de un banco experimental de bombeo para el análisis de altura neta positiva de succión en bombas centrífugas. UTC. Latacunga. 117 p.PI-002199http://repositorio.utc.edu.ec/handle/27000/9692spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2023-02-23T08:00:41Zoai:repositorio.utc.edu.ec:27000/9692Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02026-03-08T03:38:43.966430Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle Diseño de un banco experimental de bombeo para el análisis de altura neta positiva de succión en bombas centrífugas
Lema Jami, Byron Oswaldo
BOMBAS CENTRÍFUGAS
CAUDAL
NPSH
CAVITACIÓN
ELECTROMECÁNICA
status_str publishedVersion
title Diseño de un banco experimental de bombeo para el análisis de altura neta positiva de succión en bombas centrífugas
title_full Diseño de un banco experimental de bombeo para el análisis de altura neta positiva de succión en bombas centrífugas
title_fullStr Diseño de un banco experimental de bombeo para el análisis de altura neta positiva de succión en bombas centrífugas
title_full_unstemmed Diseño de un banco experimental de bombeo para el análisis de altura neta positiva de succión en bombas centrífugas
title_short Diseño de un banco experimental de bombeo para el análisis de altura neta positiva de succión en bombas centrífugas
title_sort Diseño de un banco experimental de bombeo para el análisis de altura neta positiva de succión en bombas centrífugas
topic BOMBAS CENTRÍFUGAS
CAUDAL
NPSH
CAVITACIÓN
ELECTROMECÁNICA
url http://repositorio.utc.edu.ec/handle/27000/9692