Evaluación de las pérdidas de energía eléctrica en los equipos e instalaciones del laboratorio de mecánica industrial de la Universidad de las Fuerzas Armadas ESPE extensión Latacunga, durante el año 2017. propuesta de un plan de mejoras para el uso eficiente de la energía eléctrica

To improve energy efficiency the first step is always to measure. An energy audit allows to know the current situation, data on consumption, energy costs, in addition to reduce energy consumption and identify the areas that allow a potential energy saving. The research is divided into 4 Chapters, th...

Description complète

Enregistré dans:
Détails bibliographiques
Auteur principal: Ibáñez Jácome, Pepe Fernando (author)
Format: masterThesis
Langue:spa
Publié: 2018
Sujets:
Accès en ligne:http://repositorio.utc.edu.ec/handle/27000/11159
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1822282063570534400
author Ibáñez Jácome, Pepe Fernando
author_facet Ibáñez Jácome, Pepe Fernando
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv Moreano Martínez, Edwin Homero
dc.creator.none.fl_str_mv Ibáñez Jácome, Pepe Fernando
dc.date.none.fl_str_mv 2018-10
2023-09-27T17:00:20Z
2023-09-27T17:00:20Z
dc.format.none.fl_str_mv 107 páginas
dc.identifier.none.fl_str_mv Pepe Fernando Ibáñez Jácome (2018); Evaluación de las pérdidas de energía Eléctrica en los equipos e instalaciones del laboratorio de mecánica industrial de la Universidad de las Fuerzas Armadas ESPE extensión Latacunga, durante el año 2017. propuesta de un plan de mejoras para el uso eficiente de la energía eléctrica. UTC. Latacunga 107 p.
MUTC-001650
http://repositorio.utc.edu.ec/handle/27000/11159
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador : Latacunga: Universidad Técnica de Cotopaxi (UTC)
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv AUDITORÍA ENERGÉTICA
EFICIENCIA ENERGÉTICA
AHORRO DE ENERGÍA
PLAN DE MEJORAS
EQUIPOS DE MEDICIÓN
INSTALACIÓN ELÉCTRICA
FACTOR DE POTENCIA
GESTIÓN DE ENERGÍAS
dc.title.none.fl_str_mv Evaluación de las pérdidas de energía eléctrica en los equipos e instalaciones del laboratorio de mecánica industrial de la Universidad de las Fuerzas Armadas ESPE extensión Latacunga, durante el año 2017. propuesta de un plan de mejoras para el uso eficiente de la energía eléctrica
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/masterThesis
description To improve energy efficiency the first step is always to measure. An energy audit allows to know the current situation, data on consumption, energy costs, in addition to reduce energy consumption and identify the areas that allow a potential energy saving. The research is divided into 4 Chapters, the first is the state of art of the electrical parameters for the simulation of electrical consumption and the methods of optimization of energy, Chapter II addresses the research methodology by determining the tools with which will perform the research work and the sample for surveys in the laboratory of mechanical industry, in III, the results of the data obtained will be presented and the IV is the proposal of an improvement plan to reduce losses and improve quality of electric power. The results of the measurements showed that in the main board the quality of the energy was adequate, there being some voltage variations in the lines that feed the equipment, an acceptable power factor of 0.92, in turn the load of the transformer was at the limit of its capacity with a value of 93.4%, with the laboratory being 33.71% of the load of the transformer. The actions proposed in the improvement plan, such as balancing laboratory loads, making the circuit independent with a new transformer and replacing the luminaires, will reduce losses and improve the quality of energy.
eu_rights_str_mv openAccess
format masterThesis
id UTC_cf5dd8f53bb8b849bc6046ee174eb5cb
identifier_str_mv Pepe Fernando Ibáñez Jácome (2018); Evaluación de las pérdidas de energía Eléctrica en los equipos e instalaciones del laboratorio de mecánica industrial de la Universidad de las Fuerzas Armadas ESPE extensión Latacunga, durante el año 2017. propuesta de un plan de mejoras para el uso eficiente de la energía eléctrica. UTC. Latacunga 107 p.
MUTC-001650
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:oai:repositorio.utc.edu.ec:27000:27000/11159
publishDate 2018
publisher.none.fl_str_mv Ecuador : Latacunga: Universidad Técnica de Cotopaxi (UTC)
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Evaluación de las pérdidas de energía eléctrica en los equipos e instalaciones del laboratorio de mecánica industrial de la Universidad de las Fuerzas Armadas ESPE extensión Latacunga, durante el año 2017. propuesta de un plan de mejoras para el uso eficiente de la energía eléctricaIbáñez Jácome, Pepe FernandoAUDITORÍA ENERGÉTICAEFICIENCIA ENERGÉTICAAHORRO DE ENERGÍAPLAN DE MEJORASEQUIPOS DE MEDICIÓNINSTALACIÓN ELÉCTRICAFACTOR DE POTENCIAGESTIÓN DE ENERGÍASTo improve energy efficiency the first step is always to measure. An energy audit allows to know the current situation, data on consumption, energy costs, in addition to reduce energy consumption and identify the areas that allow a potential energy saving. The research is divided into 4 Chapters, the first is the state of art of the electrical parameters for the simulation of electrical consumption and the methods of optimization of energy, Chapter II addresses the research methodology by determining the tools with which will perform the research work and the sample for surveys in the laboratory of mechanical industry, in III, the results of the data obtained will be presented and the IV is the proposal of an improvement plan to reduce losses and improve quality of electric power. The results of the measurements showed that in the main board the quality of the energy was adequate, there being some voltage variations in the lines that feed the equipment, an acceptable power factor of 0.92, in turn the load of the transformer was at the limit of its capacity with a value of 93.4%, with the laboratory being 33.71% of the load of the transformer. The actions proposed in the improvement plan, such as balancing laboratory loads, making the circuit independent with a new transformer and replacing the luminaires, will reduce losses and improve the quality of energy.El presenta trabajo contiene un plan de mejoras para la eficiencia energética que de fundamenta en una auditoría energética permite conocer la situación actual, datos sobre consumos, costos de energía, además reducir los consumos de energía e identificar las áreas que permitan un potencial ahorro de energía. La investigación se divide en 4 Capítulos, el primero es el estado de arte de los parámetros eléctricos para la simulación del consumo eléctrico y los métodos de optimización de laenergía, el Capítulo II aborda la metodología de la investigación determinando lasherramientas con las cuales se realizará el trabajo de investigación y la muestra para lasencuestas en el laboratorio de mecánica industrial, en el III, se presentan los resultados de los datos obtenidos y el IV es la propuesta de un plan de mejoras para reducir las pérdidas y mejorar la calidad de la energía eléctrica. Los resultados de las mediciones mostraron que en el tablero principal la calidad de la energía no era adecuada, existiendo algunas variaciones de voltaje en las líneas que alimentan los equipos, un aceptable factor de potencia de 0.92, a su vez la carga del transformador se encontraba al límite de su capacidad instalada en función de su dimensionamiento establecido, representando el consumo de operación del laboratorio en las horas pico de funcionamiento, una carga importante del transformador. Las acciones propuestas en el plan de mejoras, como balancear las cargas del laboratorio, independizar el circuito con un nuevo transformador y sustituir las luminarias, permitirán reducir las pérdidas y mejorar la calidad de la energíaEcuador : Latacunga: Universidad Técnica de Cotopaxi (UTC)Moreano Martínez, Edwin Homero2023-09-27T17:00:20Z2023-09-27T17:00:20Z2018-10info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis107 páginasPepe Fernando Ibáñez Jácome (2018); Evaluación de las pérdidas de energía Eléctrica en los equipos e instalaciones del laboratorio de mecánica industrial de la Universidad de las Fuerzas Armadas ESPE extensión Latacunga, durante el año 2017. propuesta de un plan de mejoras para el uso eficiente de la energía eléctrica. UTC. Latacunga 107 p.MUTC-001650http://repositorio.utc.edu.ec/handle/27000/11159spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2023-09-28T08:01:13Zoai:oai:repositorio.utc.edu.ec:27000:27000/11159Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02025-01-26T03:45:59.189073Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle Evaluación de las pérdidas de energía eléctrica en los equipos e instalaciones del laboratorio de mecánica industrial de la Universidad de las Fuerzas Armadas ESPE extensión Latacunga, durante el año 2017. propuesta de un plan de mejoras para el uso eficiente de la energía eléctrica
Ibáñez Jácome, Pepe Fernando
AUDITORÍA ENERGÉTICA
EFICIENCIA ENERGÉTICA
AHORRO DE ENERGÍA
PLAN DE MEJORAS
EQUIPOS DE MEDICIÓN
INSTALACIÓN ELÉCTRICA
FACTOR DE POTENCIA
GESTIÓN DE ENERGÍAS
status_str publishedVersion
title Evaluación de las pérdidas de energía eléctrica en los equipos e instalaciones del laboratorio de mecánica industrial de la Universidad de las Fuerzas Armadas ESPE extensión Latacunga, durante el año 2017. propuesta de un plan de mejoras para el uso eficiente de la energía eléctrica
title_full Evaluación de las pérdidas de energía eléctrica en los equipos e instalaciones del laboratorio de mecánica industrial de la Universidad de las Fuerzas Armadas ESPE extensión Latacunga, durante el año 2017. propuesta de un plan de mejoras para el uso eficiente de la energía eléctrica
title_fullStr Evaluación de las pérdidas de energía eléctrica en los equipos e instalaciones del laboratorio de mecánica industrial de la Universidad de las Fuerzas Armadas ESPE extensión Latacunga, durante el año 2017. propuesta de un plan de mejoras para el uso eficiente de la energía eléctrica
title_full_unstemmed Evaluación de las pérdidas de energía eléctrica en los equipos e instalaciones del laboratorio de mecánica industrial de la Universidad de las Fuerzas Armadas ESPE extensión Latacunga, durante el año 2017. propuesta de un plan de mejoras para el uso eficiente de la energía eléctrica
title_short Evaluación de las pérdidas de energía eléctrica en los equipos e instalaciones del laboratorio de mecánica industrial de la Universidad de las Fuerzas Armadas ESPE extensión Latacunga, durante el año 2017. propuesta de un plan de mejoras para el uso eficiente de la energía eléctrica
title_sort Evaluación de las pérdidas de energía eléctrica en los equipos e instalaciones del laboratorio de mecánica industrial de la Universidad de las Fuerzas Armadas ESPE extensión Latacunga, durante el año 2017. propuesta de un plan de mejoras para el uso eficiente de la energía eléctrica
topic AUDITORÍA ENERGÉTICA
EFICIENCIA ENERGÉTICA
AHORRO DE ENERGÍA
PLAN DE MEJORAS
EQUIPOS DE MEDICIÓN
INSTALACIÓN ELÉCTRICA
FACTOR DE POTENCIA
GESTIÓN DE ENERGÍAS
url http://repositorio.utc.edu.ec/handle/27000/11159