Implementación de un sistema para la obtención de la eficiencia y calidad de energía en el sistema de bombeo de la Universidad Técnica de Cotopaxi

The objective of this technological proposal is the implementation of a data acquisition system for the analysis of the efficiency and quality of the energy of the pumping system, through the recording of measurements of different electrical parameters, to determine the current status and behavior o...

Descripció completa

Guardat en:
Dades bibliogràfiques
Autor principal: Gavilanes Azogue, Wilson Efraín (author)
Altres autors: Vega Vega, Norma Jessica (author)
Format: bachelorThesis
Idioma:spa
Publicat: 2022
Matèries:
Accés en línia:http://repositorio.utc.edu.ec/handle/27000/9660
Etiquetes: Afegir etiqueta
Sense etiquetes, Sigues el primer a etiquetar aquest registre!
Descripció
Sumari:The objective of this technological proposal is the implementation of a data acquisition system for the analysis of the efficiency and quality of the energy of the pumping system, through the recording of measurements of different electrical parameters, to determine the current status and behavior of the pumping system. The study arose from the need to analyze the parameters of quality and efficiency of the power supply in the bar that feeds the system, limiting the monitoring of electrical parameters, the methodology used is of an applicative nature with the use of bibliographic, experimental and field sources, with the use of the CVM-A 1500 network analyzer, which allowed analyzing the behavior of the network, in a period of 7 days, as established by the regulation Agency for Regulation and Control of Energy and Non-Renewable Natural Resources, Starting from July 7, 2022 to July 13, 2022, from 7 am to 19 pm, through which we proceeded to the acquisition of data in Excel format to obtain the behavior of each of the electrical parameters, where an average voltage level was obtained in the L1 of 130, 94 V, L2 131.66 V, and in L3 131.66 V, when analyzing the voltage harmonics data it was determined that during the 7 days it reflects an average of 0.410 % in L1, average of 0.382 % in L2 and 0.561 % in L3, which is within the established limit of 5 %. In the analysis of current harmonics it was determined that in L1 2.294 %, in L2 2.291 % and in L3 2.2 %, which are between the established limits of 4 %, when analyzing the active power it was determined that the system is unbalanced in 4.44 %, that is, the system is within the established range of 5 %. Among the conclusions, it is worth mentioning that the quality parameters of the pumping system are within the range established by ARCERNNR 002/20.