Factor antropométrico aplicado al diseño de monturas oftálmicas mediante escaneo e impresión 3D.

The following project focuses on students and teachers from Applied Sciences and Engineering Department in Cotopaxi Technical University in Latacunga city Ecuador. The majority of them require a regular use of glasses due to multiple vision issues. Since glasses are a device used frequently, it is e...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Autor principal: Sarzosa García, Karina Elizabeth (author)
Outros Autores: Vallejo Armas, Carlos David (author)
Formato: bachelorThesis
Idioma:spa
Publicado em: 2019
Assuntos:
Acesso em linha:http://repositorio.utc.edu.ec/handle/27000/5486
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
_version_ 1822282027933630464
author Sarzosa García, Karina Elizabeth
author2 Vallejo Armas, Carlos David
author2_role author
author_facet Sarzosa García, Karina Elizabeth
Vallejo Armas, Carlos David
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv Hidalgo, Angel
dc.creator.none.fl_str_mv Sarzosa García, Karina Elizabeth
Vallejo Armas, Carlos David
dc.date.none.fl_str_mv 2019-02
2020-07-24T21:07:16Z
2020-07-24T21:07:16Z
dc.format.none.fl_str_mv 58 páginas
dc.identifier.none.fl_str_mv Sarzosa García.K.E.(2019) Factor antropométrico aplicado al diseño de monturas oftálmicas mediante escaneo e impresión 3D. UTC. Latacunga. 58 P.
T-001081
http://repositorio.utc.edu.ec/handle/27000/5486
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi: Facultad de Ciencias de la Ingeniería y Aplicadas
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv Ingeniería Industrial
Escaneo 3D
Montura oftálmica
Tecnología
dc.title.none.fl_str_mv Factor antropométrico aplicado al diseño de monturas oftálmicas mediante escaneo e impresión 3D.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description The following project focuses on students and teachers from Applied Sciences and Engineering Department in Cotopaxi Technical University in Latacunga city Ecuador. The majority of them require a regular use of glasses due to multiple vision issues. Since glasses are a device used frequently, it is evident various specific problems they can cause. This fact, due to the standard size and weight under which glasses are manufactured. It results in discomforts such as pain and pressure marks over face areas and the head (nasal bone, temporal bone, temple and nape). The project aims to design a prototype of eyeglasses frame based on anthropometric factors taken from three dimensional (3D) scanning. One of the methodologies used was a survey to clearly understand the customer's needs. Once the survey was completed, a person was selected to determine the roots of his problems due to the commercial frame he usually uses. To do so, a 3D scanning was run with the person to acquire real measurements. At the end of the process, the new frame fitted precisely the head shape of the individual. Part of the process involved a software package were several parameters for the design were chosen (color, size, customizing). After the draft version of the frame was obtained using a 3D printer, the feedback was applied with the individual. Basically, from the 3D scanning, a nonsymmetrical facial characteristic was detected. By comparing the commercial eyeglasses frame with the customized one, the origin of the problem was concluded.
eu_rights_str_mv openAccess
format bachelorThesis
id UTC_ee52daf7ea0173efa420f0e0b6ff2bf2
identifier_str_mv Sarzosa García.K.E.(2019) Factor antropométrico aplicado al diseño de monturas oftálmicas mediante escaneo e impresión 3D. UTC. Latacunga. 58 P.
T-001081
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:oai:repositorio.utc.edu.ec:27000:27000/5486
publishDate 2019
publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi: Facultad de Ciencias de la Ingeniería y Aplicadas
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Factor antropométrico aplicado al diseño de monturas oftálmicas mediante escaneo e impresión 3D.Sarzosa García, Karina ElizabethVallejo Armas, Carlos DavidIngeniería IndustrialEscaneo 3DMontura oftálmicaTecnologíaThe following project focuses on students and teachers from Applied Sciences and Engineering Department in Cotopaxi Technical University in Latacunga city Ecuador. The majority of them require a regular use of glasses due to multiple vision issues. Since glasses are a device used frequently, it is evident various specific problems they can cause. This fact, due to the standard size and weight under which glasses are manufactured. It results in discomforts such as pain and pressure marks over face areas and the head (nasal bone, temporal bone, temple and nape). The project aims to design a prototype of eyeglasses frame based on anthropometric factors taken from three dimensional (3D) scanning. One of the methodologies used was a survey to clearly understand the customer's needs. Once the survey was completed, a person was selected to determine the roots of his problems due to the commercial frame he usually uses. To do so, a 3D scanning was run with the person to acquire real measurements. At the end of the process, the new frame fitted precisely the head shape of the individual. Part of the process involved a software package were several parameters for the design were chosen (color, size, customizing). After the draft version of the frame was obtained using a 3D printer, the feedback was applied with the individual. Basically, from the 3D scanning, a nonsymmetrical facial characteristic was detected. By comparing the commercial eyeglasses frame with the customized one, the origin of the problem was concluded.El presente proyecto está enfocado a los estudiantes y docentes de la Facultad de Ciencias de la Ingeniería y Aplicadas de la Universidad Técnica de Cotopaxi de la ciudad de LatacungaEcuador, quienes mayoritariamente requieren el uso constante de lentes por diversas razones. Al ser un producto de uso permanente se evidencian varios problemas causados específicamente por el tamaño y peso de los mismos, debido a que estos productos son fabricados con medidas estándar. Esto ocasiona molestias como, dolor y enrojecimiento en las zonas del rostro y cabeza (hueso nasal, hueso temporal, sien y nuca). El proyecto tiene como objetivo diseñar un prototipo de montura oftálmica en base al factor antropométrico mediante escaneo e impresión 3D (tridimensional), utilizando la metodología con un enfoque de tipo exploratoria, que permitió conocer las necesidades y requerimientos de las personas a través de una encuesta. Posteriormente se eligió a un sujeto de prueba para determinar las causas de los problemas que presentaba al utilizar una montura oftálmica estándar, esto tomando las medidas mediante el escaneo 3D para obtener datos reales de la forma de rostro y cabeza, logrando así determinar las medidas precisas necesarias como condición para la fabricación del producto. Continuando con el diseñó del prototipo de la montura oftálmica por medio de una herramienta virtual que permitió cumplir con todos los requerimientos de diseño como: color, tamaño, estética y forma, plasmando el boceto virtual en un producto real utilizando la impresión 3D y finalmente se desarrolló una retroalimentación, donde se detectó que la persona presentaba una característica facial no simétrica, misma que fue solucionada a través de la tecnología antes mencionada y también se comparó las dos monturas obteniendo diferenciación de medidas notorias llegando así a la conclusión de que esta era la raíz de los problemas que padecía al principio de esta investigación.Ecuador: Latacunga: Universidad Técnica de Cotopaxi: Facultad de Ciencias de la Ingeniería y AplicadasHidalgo, Angel2020-07-24T21:07:16Z2020-07-24T21:07:16Z2019-02info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis58 páginasSarzosa García.K.E.(2019) Factor antropométrico aplicado al diseño de monturas oftálmicas mediante escaneo e impresión 3D. UTC. Latacunga. 58 P.T-001081http://repositorio.utc.edu.ec/handle/27000/5486spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2020-07-25T08:00:30Zoai:oai:repositorio.utc.edu.ec:27000:27000/5486Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02025-01-26T03:44:13.680643Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle Factor antropométrico aplicado al diseño de monturas oftálmicas mediante escaneo e impresión 3D.
Sarzosa García, Karina Elizabeth
Ingeniería Industrial
Escaneo 3D
Montura oftálmica
Tecnología
status_str publishedVersion
title Factor antropométrico aplicado al diseño de monturas oftálmicas mediante escaneo e impresión 3D.
title_full Factor antropométrico aplicado al diseño de monturas oftálmicas mediante escaneo e impresión 3D.
title_fullStr Factor antropométrico aplicado al diseño de monturas oftálmicas mediante escaneo e impresión 3D.
title_full_unstemmed Factor antropométrico aplicado al diseño de monturas oftálmicas mediante escaneo e impresión 3D.
title_short Factor antropométrico aplicado al diseño de monturas oftálmicas mediante escaneo e impresión 3D.
title_sort Factor antropométrico aplicado al diseño de monturas oftálmicas mediante escaneo e impresión 3D.
topic Ingeniería Industrial
Escaneo 3D
Montura oftálmica
Tecnología
url http://repositorio.utc.edu.ec/handle/27000/5486