Análisis comparativo del rendimiento térmico de un colector solar de placa plana variando el tipo de vidrio en la cubierta.
This work studied the process of thermal exchange that occurs in a mass flow of air due to incident solar radiation and ambient temperature, two flat plate solar collectors were used to which two dark and light conventional glasses were applied to determine the incidence that it has on the air outle...
Gorde:
| Egile nagusia: | |
|---|---|
| Formatua: | masterThesis |
| Hizkuntza: | spa |
| Argitaratua: |
2022
|
| Gaiak: | |
| Sarrera elektronikoa: | http://repositorio.utc.edu.ec/handle/27000/10667 |
| Etiketak: |
Etiketa erantsi
Etiketarik gabe, Izan zaitez lehena erregistro honi etiketa jartzen!
|
| _version_ | 1859064110340112384 |
|---|---|
| author | Albarracín Alvarez, Mauro Darío |
| author_facet | Albarracín Alvarez, Mauro Darío |
| author_role | author |
| collection | Repositorio Universidad Técnica de Cotopaxi |
| dc.contributor.none.fl_str_mv | Torres, Enrique |
| dc.creator.none.fl_str_mv | Albarracín Alvarez, Mauro Darío |
| dc.date.none.fl_str_mv | 2022 2023-07-25T15:02:14Z 2023-07-25T15:02:14Z |
| dc.format.none.fl_str_mv | 52 páginas application/pdf |
| dc.identifier.none.fl_str_mv | Albarracín Alvarez, Mauro Darío (2022), Análisis comparativo del rendimiento térmico de un colector solar de placa plana variando el tipo de vidrio en la cubierta. Latacunga. UTC. 52 p. MUTC-001269 http://repositorio.utc.edu.ec/handle/27000/10667 |
| dc.language.none.fl_str_mv | spa |
| dc.publisher.none.fl_str_mv | Ecuador : Latacunga: Universidad Técnica de Cotopaxi (UTC) |
| dc.rights.none.fl_str_mv | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ info:eu-repo/semantics/openAccess |
| dc.source.none.fl_str_mv | reponame:Repositorio Universidad Técnica de Cotopaxi instname:Universidad Técnica de Cotopaxi instacron:UTC |
| dc.subject.none.fl_str_mv | COLECTOR SOLAR RENDIMIENTO TÉRMICO COMPARACIÓN DE CUBIERTA ELECTROMECÁNICA |
| dc.title.none.fl_str_mv | Análisis comparativo del rendimiento térmico de un colector solar de placa plana variando el tipo de vidrio en la cubierta. |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/masterThesis |
| description | This work studied the process of thermal exchange that occurs in a mass flow of air due to incident solar radiation and ambient temperature, two flat plate solar collectors were used to which two dark and light conventional glasses were applied to determine the incidence that it has on the air outlet temperature, the object was to establish the comparison of the behavior of the collectors and their thermal performance when varying the type of cover, experiments were carried out under equal conditions with data collection in real time every minute for six hours a day and four conditions, without forced air, with forced air at 6.2 m/s, 9.5 m/s and 11.5 m/s, the experimentation allowed us to define that the application of dark glass decreases the thermal performance, better performance is obtained when using clear glass, the outlet temperature being higher with an average value of 8.26o C without forced air, when using forced air the average temperature variation of the collector with light glass compared to dark glass is 0.58o C at 6.2 m/s, with measured radiation values from 383.5 W/ m2 (there may be lower values) 0.28oC at 9.5m/s with radiation from 331.1 W/m2 and 0.15oC at 11.5 m/s with radiation from 1090.1 W/m2. |
| eu_rights_str_mv | openAccess |
| format | masterThesis |
| id | UTC_f58cb567e4bce1197d3d5b92f48a976d |
| identifier_str_mv | Albarracín Alvarez, Mauro Darío (2022), Análisis comparativo del rendimiento térmico de un colector solar de placa plana variando el tipo de vidrio en la cubierta. Latacunga. UTC. 52 p. MUTC-001269 |
| instacron_str | UTC |
| institution | UTC |
| instname_str | Universidad Técnica de Cotopaxi |
| language | spa |
| network_acronym_str | UTC |
| network_name_str | Repositorio Universidad Técnica de Cotopaxi |
| oai_identifier_str | oai:repositorio.utc.edu.ec:27000/10667 |
| publishDate | 2022 |
| publisher.none.fl_str_mv | Ecuador : Latacunga: Universidad Técnica de Cotopaxi (UTC) |
| reponame_str | Repositorio Universidad Técnica de Cotopaxi |
| repository.mail.fl_str_mv | . |
| repository.name.fl_str_mv | Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi |
| repository_id_str | 0 |
| rights_invalid_str_mv | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ |
| spelling | Análisis comparativo del rendimiento térmico de un colector solar de placa plana variando el tipo de vidrio en la cubierta.Albarracín Alvarez, Mauro DaríoCOLECTOR SOLARRENDIMIENTO TÉRMICOCOMPARACIÓN DE CUBIERTAELECTROMECÁNICAThis work studied the process of thermal exchange that occurs in a mass flow of air due to incident solar radiation and ambient temperature, two flat plate solar collectors were used to which two dark and light conventional glasses were applied to determine the incidence that it has on the air outlet temperature, the object was to establish the comparison of the behavior of the collectors and their thermal performance when varying the type of cover, experiments were carried out under equal conditions with data collection in real time every minute for six hours a day and four conditions, without forced air, with forced air at 6.2 m/s, 9.5 m/s and 11.5 m/s, the experimentation allowed us to define that the application of dark glass decreases the thermal performance, better performance is obtained when using clear glass, the outlet temperature being higher with an average value of 8.26o C without forced air, when using forced air the average temperature variation of the collector with light glass compared to dark glass is 0.58o C at 6.2 m/s, with measured radiation values from 383.5 W/ m2 (there may be lower values) 0.28oC at 9.5m/s with radiation from 331.1 W/m2 and 0.15oC at 11.5 m/s with radiation from 1090.1 W/m2.Este trabajo estudió el proceso de intercambio térmico que se produce en un flujo másico de aire debido a la radiación solar incidente y temperatura ambiente, se utilizó dos colectores solares de placa plana a los que se les aplicó dos vidrios convencionales oscuro y claro para determinar la incidencia que tiene en la temperatura de salida del aire, el objeto fue establecer la comparación del comportamiento de los colectores y su rendimiento térmico al variar el tipo de cubierta, se trabajó con experimentos en igualdad de condiciones con toma de datos en tiempo real cada minuto durante seis horas al día y cuatro condiciones, sin aire forzado, con aire forzado a 6.2 m/s , 9.5 m/s y 11.5 m/s, la experimentación permitió definir que la aplicación de vidrio oscuro disminuye el rendimiento térmico, se obtiene mejor rendimiento al utilizar vidrio claro siendo la temperatura de salida mayor con un valor promedio de 8.26o C sin aire forzado, al utilizar aire forzado la variación promedio de temperatura del colector con vidrio claro con respecto al oscuro es de 0.58o C a 6.2 m/s, con valores de radiación medidas desde 383.5 W/m2 ( puede haber valores inferiores) 0.28oC a 9.5m/s con radiaciones a partir de 331.1 W/m2 y 0.15oC a 11.5 m/s con radiaciones a partir de 1090.1 W/m2.Ecuador : Latacunga: Universidad Técnica de Cotopaxi (UTC)Torres, Enrique2023-07-25T15:02:14Z2023-07-25T15:02:14Z2022info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis52 páginasapplication/pdfAlbarracín Alvarez, Mauro Darío (2022), Análisis comparativo del rendimiento térmico de un colector solar de placa plana variando el tipo de vidrio en la cubierta. Latacunga. UTC. 52 p.MUTC-001269http://repositorio.utc.edu.ec/handle/27000/10667spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2023-07-26T08:00:28Zoai:repositorio.utc.edu.ec:27000/10667Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02026-03-08T03:41:33.041192Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue |
| spellingShingle | Análisis comparativo del rendimiento térmico de un colector solar de placa plana variando el tipo de vidrio en la cubierta. Albarracín Alvarez, Mauro Darío COLECTOR SOLAR RENDIMIENTO TÉRMICO COMPARACIÓN DE CUBIERTA ELECTROMECÁNICA |
| status_str | publishedVersion |
| title | Análisis comparativo del rendimiento térmico de un colector solar de placa plana variando el tipo de vidrio en la cubierta. |
| title_full | Análisis comparativo del rendimiento térmico de un colector solar de placa plana variando el tipo de vidrio en la cubierta. |
| title_fullStr | Análisis comparativo del rendimiento térmico de un colector solar de placa plana variando el tipo de vidrio en la cubierta. |
| title_full_unstemmed | Análisis comparativo del rendimiento térmico de un colector solar de placa plana variando el tipo de vidrio en la cubierta. |
| title_short | Análisis comparativo del rendimiento térmico de un colector solar de placa plana variando el tipo de vidrio en la cubierta. |
| title_sort | Análisis comparativo del rendimiento térmico de un colector solar de placa plana variando el tipo de vidrio en la cubierta. |
| topic | COLECTOR SOLAR RENDIMIENTO TÉRMICO COMPARACIÓN DE CUBIERTA ELECTROMECÁNICA |
| url | http://repositorio.utc.edu.ec/handle/27000/10667 |