Diseño de un sistema de protección de los generadores en conexión y no aterrizados para detectar fallas a tierra en la central hidroeléctrica “la península” perteneciente a la EEASA en el período agosto 2013 – agosto 2014
The design of the electrical protections made by computerized systems is necessary in a power generation as it receives all abnormal conditions in an electrical system. In much of electric generators such as La Peninsula belonging to the Utility Ambato EEASA have no system ground, this system was ma...
保存先:
| 第一著者: | |
|---|---|
| フォーマット: | bachelorThesis |
| 言語: | spa |
| 出版事項: |
2015
|
| 主題: | |
| オンライン・アクセス: | http://repositorio.utc.edu.ec/handle/27000/2958 |
| タグ: |
タグ追加
タグなし, このレコードへの初めてのタグを付けませんか!
|
| _version_ | 1858430317058064384 |
|---|---|
| author | Culqui Moposita, Wilson Tarquino |
| author_facet | Culqui Moposita, Wilson Tarquino |
| author_role | author |
| collection | Repositorio Universidad Técnica de Cotopaxi |
| dc.contributor.none.fl_str_mv | Barrera, Marcelo |
| dc.creator.none.fl_str_mv | Culqui Moposita, Wilson Tarquino |
| dc.date.none.fl_str_mv | 2015 2016-10-11T19:44:38Z 2016-10-11T19:44:38Z |
| dc.format.none.fl_str_mv | 79 p. application/pdf |
| dc.identifier.none.fl_str_mv | Culqui Moposita, Wilson Tarquino (2015). Diseño de un sistema de protección de los generadores en conexión y no aterrizados para detectar fallas a tierra en la central hidroeléctrica “la península” perteneciente a la EEASA en el período agosto 2013 – agosto 2014. Ingeniería Eléctrica. UTC. Latacunga. 79 p. http://repositorio.utc.edu.ec/handle/27000/2958 |
| dc.language.none.fl_str_mv | spa |
| dc.publisher.none.fl_str_mv | LATACUNGA / UTC / 2015 |
| dc.rights.none.fl_str_mv | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ info:eu-repo/semantics/openAccess |
| dc.source.none.fl_str_mv | reponame:Repositorio Universidad Técnica de Cotopaxi instname:Universidad Técnica de Cotopaxi instacron:UTC |
| dc.subject.none.fl_str_mv | DISEÑO SISTEMA DE PROTECCIÓN GENERADORES CENTRAL HIDROELÉCTRICA |
| dc.title.none.fl_str_mv | Diseño de un sistema de protección de los generadores en conexión y no aterrizados para detectar fallas a tierra en la central hidroeléctrica “la península” perteneciente a la EEASA en el período agosto 2013 – agosto 2014 |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/bachelorThesis |
| description | The design of the electrical protections made by computerized systems is necessary in a power generation as it receives all abnormal conditions in an electrical system. In much of electric generators such as La Peninsula belonging to the Utility Ambato EEASA have no system ground, this system was made for the generators out of operation as there is a ground fault and can continue to run, but if the fault persists healthy drivers would be subject to high voltages up to 1,73 times, this situation causes premature aging of the insulation system and a second failure will next time.... |
| eu_rights_str_mv | openAccess |
| format | bachelorThesis |
| id | UTC_f9dc2f422bb283fa640ff32ef2915039 |
| identifier_str_mv | Culqui Moposita, Wilson Tarquino (2015). Diseño de un sistema de protección de los generadores en conexión y no aterrizados para detectar fallas a tierra en la central hidroeléctrica “la península” perteneciente a la EEASA en el período agosto 2013 – agosto 2014. Ingeniería Eléctrica. UTC. Latacunga. 79 p. |
| instacron_str | UTC |
| institution | UTC |
| instname_str | Universidad Técnica de Cotopaxi |
| language | spa |
| network_acronym_str | UTC |
| network_name_str | Repositorio Universidad Técnica de Cotopaxi |
| oai_identifier_str | oai:repositorio.utc.edu.ec:27000/2958 |
| publishDate | 2015 |
| publisher.none.fl_str_mv | LATACUNGA / UTC / 2015 |
| reponame_str | Repositorio Universidad Técnica de Cotopaxi |
| repository.mail.fl_str_mv | . |
| repository.name.fl_str_mv | Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi |
| repository_id_str | 0 |
| rights_invalid_str_mv | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ |
| spelling | Diseño de un sistema de protección de los generadores en conexión y no aterrizados para detectar fallas a tierra en la central hidroeléctrica “la península” perteneciente a la EEASA en el período agosto 2013 – agosto 2014Culqui Moposita, Wilson TarquinoDISEÑOSISTEMA DE PROTECCIÓNGENERADORESCENTRAL HIDROELÉCTRICAThe design of the electrical protections made by computerized systems is necessary in a power generation as it receives all abnormal conditions in an electrical system. In much of electric generators such as La Peninsula belonging to the Utility Ambato EEASA have no system ground, this system was made for the generators out of operation as there is a ground fault and can continue to run, but if the fault persists healthy drivers would be subject to high voltages up to 1,73 times, this situation causes premature aging of the insulation system and a second failure will next time....El diseño de las protecciones eléctricas realizadas por sistemas computarizados es necesario en una central de generación, ya que recibe todas las condiciones anormales de un sistema eléctrico. En mucho de los generadores eléctricos como es el de La Península perteneciente a la Empresa Eléctrica Ambato EEASA no presentan sistema de puesta a tierra, este sistema fue realizada para que los generadores no salga de funcionamiento cuando exista una falla a tierra y pueda seguir funcionado, pero si la falla persiste los conductores sanos estaría sometidos a voltajes elevados hasta de 1,73 veces, esta situación causa envejecimiento prematuro del sistema de aislamiento y se tendrá una segunda falla en tiempo próximo....LATACUNGA / UTC / 2015Barrera, Marcelo2016-10-11T19:44:38Z2016-10-11T19:44:38Z2015info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis79 p.application/pdfCulqui Moposita, Wilson Tarquino (2015). Diseño de un sistema de protección de los generadores en conexión y no aterrizados para detectar fallas a tierra en la central hidroeléctrica “la península” perteneciente a la EEASA en el período agosto 2013 – agosto 2014. Ingeniería Eléctrica. UTC. Latacunga. 79 p.http://repositorio.utc.edu.ec/handle/27000/2958spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2016-10-12T08:00:08Zoai:repositorio.utc.edu.ec:27000/2958Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02026-03-01T03:44:10.841879Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue |
| spellingShingle | Diseño de un sistema de protección de los generadores en conexión y no aterrizados para detectar fallas a tierra en la central hidroeléctrica “la península” perteneciente a la EEASA en el período agosto 2013 – agosto 2014 Culqui Moposita, Wilson Tarquino DISEÑO SISTEMA DE PROTECCIÓN GENERADORES CENTRAL HIDROELÉCTRICA |
| status_str | publishedVersion |
| title | Diseño de un sistema de protección de los generadores en conexión y no aterrizados para detectar fallas a tierra en la central hidroeléctrica “la península” perteneciente a la EEASA en el período agosto 2013 – agosto 2014 |
| title_full | Diseño de un sistema de protección de los generadores en conexión y no aterrizados para detectar fallas a tierra en la central hidroeléctrica “la península” perteneciente a la EEASA en el período agosto 2013 – agosto 2014 |
| title_fullStr | Diseño de un sistema de protección de los generadores en conexión y no aterrizados para detectar fallas a tierra en la central hidroeléctrica “la península” perteneciente a la EEASA en el período agosto 2013 – agosto 2014 |
| title_full_unstemmed | Diseño de un sistema de protección de los generadores en conexión y no aterrizados para detectar fallas a tierra en la central hidroeléctrica “la península” perteneciente a la EEASA en el período agosto 2013 – agosto 2014 |
| title_short | Diseño de un sistema de protección de los generadores en conexión y no aterrizados para detectar fallas a tierra en la central hidroeléctrica “la península” perteneciente a la EEASA en el período agosto 2013 – agosto 2014 |
| title_sort | Diseño de un sistema de protección de los generadores en conexión y no aterrizados para detectar fallas a tierra en la central hidroeléctrica “la península” perteneciente a la EEASA en el período agosto 2013 – agosto 2014 |
| topic | DISEÑO SISTEMA DE PROTECCIÓN GENERADORES CENTRAL HIDROELÉCTRICA |
| url | http://repositorio.utc.edu.ec/handle/27000/2958 |