Ubicación y dimensionamiento óptimo de generación distribuida (GD) en redes de distribución radial.

The present research bases its content on Distributed Generation (DG) ,which compared to an electrical distribution system, provides clean and reliable energy thanks to its optimal location and dimensioning; it is known that, the DGs supply active power to the network, this causes that it diminishes...

Бүрэн тодорхойлолт

-д хадгалсан:
Номзүйн дэлгэрэнгүй
Үндсэн зохиолч: Llango Guamushig, Edgar Fabian (author)
Бусад зохиолчид: Velva Ortega, Nancy Elizabeth (author)
Формат: bachelorThesis
Хэл сонгох:spa
Хэвлэсэн: 2020
Нөхцлүүд:
Онлайн хандалт:http://repositorio.utc.edu.ec/handle/27000/7945
Шошгууд: Шошго нэмэх
Шошго байхгүй, Энэхүү баримтыг шошголох эхний хүн болох!
_version_ 1822282044084846592
author Llango Guamushig, Edgar Fabian
author2 Velva Ortega, Nancy Elizabeth
author2_role author
author_facet Llango Guamushig, Edgar Fabian
Velva Ortega, Nancy Elizabeth
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv Quinatoa, Carlos
dc.creator.none.fl_str_mv Llango Guamushig, Edgar Fabian
Velva Ortega, Nancy Elizabeth
dc.date.none.fl_str_mv 2020-09
2022-01-10T20:45:17Z
2022-01-10T20:45:17Z
dc.format.none.fl_str_mv 112 páginas
dc.identifier.none.fl_str_mv Llango Guamushig Edgar Fabian, Velva Ortega Nancy Elizabeth,(2020), Ubicación y dimensionamiento óptimo de generación distribuida (GD) en redes de distribución radial. UTC Latacunga. 112 p.
PI-001722
http://repositorio.utc.edu.ec/handle/27000/7945
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC.
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv GENERACIÓN DISTRIBUIDA
PÉRDIDAS DE POTENCIA ACTIVA
MINLP
INGENIERÍA ELÉCTRICA
dc.title.none.fl_str_mv Ubicación y dimensionamiento óptimo de generación distribuida (GD) en redes de distribución radial.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description The present research bases its content on Distributed Generation (DG) ,which compared to an electrical distribution system, provides clean and reliable energy thanks to its optimal location and dimensioning; it is known that, the DGs supply active power to the network, this causes that it diminishes partly the losses of this nature as well as the losses of reactive power, improving the profile of tension in a uniform way and reducing the currents that flow for the lines, this in turn contributes with the reduction of the losses for effect Joule. The aim of this research is to carry out an optimum location and dimensioning of the distributed generation in radial distribution networks, in order to minimize active power losses in the network and to know the active and reactive power values with which GD can be injected. This was made possible by applying the mathematical model of mixed integer non-linear optimization (MINLP), which meets the characteristics of non-linearity for our study and, based on the optimization package of GAMS and DIgSILENT was found an optimal solution in terms of minimizing active power losses. In the same way this study governs its results comparing an article evaluated by the IEEE and the University of Ain Shams, in which they work with an identical optimization model, unlike, its approach consists of injecting unlimited capacity through the GD to minimize the active power losses. Finally, it has been taken the schemes of the IEEE Test Feeder of 13 and 34 bars to apply the mathematical model MINLP and, by means of an analysis of variation when injecting from 1 to 3 GDs with 30%, 60% and 70% of penetration with respect to the total demand of the system, very satisfactory results are exposed as far as the location and dimensioning of the GD and the reduction of technical losses.
eu_rights_str_mv openAccess
format bachelorThesis
id UTC_fe3faeb454721bb0db7d70dd6ed42ee5
identifier_str_mv Llango Guamushig Edgar Fabian, Velva Ortega Nancy Elizabeth,(2020), Ubicación y dimensionamiento óptimo de generación distribuida (GD) en redes de distribución radial. UTC Latacunga. 112 p.
PI-001722
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:oai:repositorio.utc.edu.ec:27000:27000/7945
publishDate 2020
publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC.
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Ubicación y dimensionamiento óptimo de generación distribuida (GD) en redes de distribución radial.Llango Guamushig, Edgar FabianVelva Ortega, Nancy ElizabethGENERACIÓN DISTRIBUIDAPÉRDIDAS DE POTENCIA ACTIVAMINLPINGENIERÍA ELÉCTRICAThe present research bases its content on Distributed Generation (DG) ,which compared to an electrical distribution system, provides clean and reliable energy thanks to its optimal location and dimensioning; it is known that, the DGs supply active power to the network, this causes that it diminishes partly the losses of this nature as well as the losses of reactive power, improving the profile of tension in a uniform way and reducing the currents that flow for the lines, this in turn contributes with the reduction of the losses for effect Joule. The aim of this research is to carry out an optimum location and dimensioning of the distributed generation in radial distribution networks, in order to minimize active power losses in the network and to know the active and reactive power values with which GD can be injected. This was made possible by applying the mathematical model of mixed integer non-linear optimization (MINLP), which meets the characteristics of non-linearity for our study and, based on the optimization package of GAMS and DIgSILENT was found an optimal solution in terms of minimizing active power losses. In the same way this study governs its results comparing an article evaluated by the IEEE and the University of Ain Shams, in which they work with an identical optimization model, unlike, its approach consists of injecting unlimited capacity through the GD to minimize the active power losses. Finally, it has been taken the schemes of the IEEE Test Feeder of 13 and 34 bars to apply the mathematical model MINLP and, by means of an analysis of variation when injecting from 1 to 3 GDs with 30%, 60% and 70% of penetration with respect to the total demand of the system, very satisfactory results are exposed as far as the location and dimensioning of the GD and the reduction of technical losses.La presente investigación basa su contenido en la Generación Distribuida (GD) que, frente a un sistema de distribución eléctrica proporciona una energía limpia y fiable gracias a una óptima localización y dimensionamiento de los mismos; se sabe que, los GDs suministran potencia activa a la red, esto hace que disminuya en parte las pérdidas de dicha naturaleza al igual que las pérdidas de potencia reactiva, mejorando el perfil de tensión de manera uniforme y reduciendo las corrientes que fluyen por las líneas, esto a su vez contribuye con la reducción de las pérdidas por efecto Joule. El objetivo de esta investigación es realizar una óptima localización y dimensionamiento de la generación distribuida en redes de distribución tipo radial, con el fin de minimizar las pérdidas de potencia activa en la red y conocer los valores de potencia activa y reactiva con las que puede inyectar GD. Esto se hizo posible al aplicar el modelo matemático de optimización no lineal entera mixta (MINLP), el mismo que cumple con las características de no linealidad que compete a nuestro estudio y, en basado al paquete de optimización de GAMS y DIgSILENT se encontró una solución óptima en cuanto a la minimización de las pérdidas de potencia activa. De la misma manera este estudio rige sus resultados comparando un artículo evaluado por el IEEE y la Universidad de Ain Shams, en el que trabajan con un modelo de optimización idéntico, a diferencia que, su enfoque consiste en inyectar capacidad ilimitada a través del GD para minimizar las pérdidas de potencia activa. Por último, se ha tomado los esquemas del IEEE Test Feeder de 13 y 34 barras para aplicar el modelo matemático MINLP y, mediante un análisis de variación al inyectar de 1 a 3 GDs con 30%, 60% y 70% de penetración con respecto a la demanda total del sistema, se exponen resultados muy satisfactorios en cuanto a la ubicación y dimensionamiento de la GD y la reducción de pérdidas técnicas.Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC.Quinatoa, Carlos2022-01-10T20:45:17Z2022-01-10T20:45:17Z2020-09info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis112 páginasLlango Guamushig Edgar Fabian, Velva Ortega Nancy Elizabeth,(2020), Ubicación y dimensionamiento óptimo de generación distribuida (GD) en redes de distribución radial. UTC Latacunga. 112 p.PI-001722http://repositorio.utc.edu.ec/handle/27000/7945spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2022-01-11T08:00:24Zoai:oai:repositorio.utc.edu.ec:27000:27000/7945Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02025-01-26T03:44:58.760383Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle Ubicación y dimensionamiento óptimo de generación distribuida (GD) en redes de distribución radial.
Llango Guamushig, Edgar Fabian
GENERACIÓN DISTRIBUIDA
PÉRDIDAS DE POTENCIA ACTIVA
MINLP
INGENIERÍA ELÉCTRICA
status_str publishedVersion
title Ubicación y dimensionamiento óptimo de generación distribuida (GD) en redes de distribución radial.
title_full Ubicación y dimensionamiento óptimo de generación distribuida (GD) en redes de distribución radial.
title_fullStr Ubicación y dimensionamiento óptimo de generación distribuida (GD) en redes de distribución radial.
title_full_unstemmed Ubicación y dimensionamiento óptimo de generación distribuida (GD) en redes de distribución radial.
title_short Ubicación y dimensionamiento óptimo de generación distribuida (GD) en redes de distribución radial.
title_sort Ubicación y dimensionamiento óptimo de generación distribuida (GD) en redes de distribución radial.
topic GENERACIÓN DISTRIBUIDA
PÉRDIDAS DE POTENCIA ACTIVA
MINLP
INGENIERÍA ELÉCTRICA
url http://repositorio.utc.edu.ec/handle/27000/7945