Evaluación del comportamiento de la protección de distancia (21) considerando el efecto Infeed en diferentes escenarios de operación.
In the present research project, the behavior of the distance protection (21) in the Santo Domingo – Baba and Baba – Quevedo transmission lines was analyzed, before the entry of the generators connected to the Baba bus, through the use of the DigSilent software Power Factory. The project included di...
Uloženo v:
| Hlavní autor: | |
|---|---|
| Médium: | bachelorThesis |
| Jazyk: | spa |
| Vydáno: |
2023
|
| Témata: | |
| On-line přístup: | http://repositorio.utc.edu.ec/handle/27000/11255 |
| Tagy: |
Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
|
| _version_ | 1822282064242671616 |
|---|---|
| author | Padilla Choca, Paola Jaqueline |
| author_facet | Padilla Choca, Paola Jaqueline |
| author_role | author |
| collection | Repositorio Universidad Técnica de Cotopaxi |
| dc.contributor.none.fl_str_mv | Proaño Maldonado, Xavier Alfonso |
| dc.creator.none.fl_str_mv | Padilla Choca, Paola Jaqueline |
| dc.date.none.fl_str_mv | 2023-09-28T16:22:54Z 2023-09-28T16:22:54Z 2023-08 |
| dc.format.none.fl_str_mv | 85 páginas |
| dc.identifier.none.fl_str_mv | Padilla Choca Paola Jaqueline (2023); Evaluación del comportamiento de la protección de distancia (21) considerando el efecto Infeed en diferentes escenarios de operación. UTC. Latacunga. 85 p. PI-002620 http://repositorio.utc.edu.ec/handle/27000/11255 |
| dc.language.none.fl_str_mv | spa |
| dc.publisher.none.fl_str_mv | Ecuador : Latacunga: Universidad Técnica de Cotopaxi (UTC) |
| dc.rights.none.fl_str_mv | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ info:eu-repo/semantics/openAccess |
| dc.source.none.fl_str_mv | reponame:Repositorio Universidad Técnica de Cotopaxi instname:Universidad Técnica de Cotopaxi instacron:UTC |
| dc.subject.none.fl_str_mv | EFECTO INFEED FALLAS DISTANCIAS DE FALLAS RELÉ DE DISTANCIA ELECTRICIDAD |
| dc.title.none.fl_str_mv | Evaluación del comportamiento de la protección de distancia (21) considerando el efecto Infeed en diferentes escenarios de operación. |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/bachelorThesis |
| description | In the present research project, the behavior of the distance protection (21) in the Santo Domingo – Baba and Baba – Quevedo transmission lines was analyzed, before the entry of the generators connected to the Baba bus, through the use of the DigSilent software Power Factory. The project included distance relays at the ends of the Santo Domingo – Baba and Baba – Quevedo transmission lines; the calibration of the protections was carried out without considering the generators connected to the Baba bar. Thus, when a generator enters the system, the protection presents problems to act in zone 2, because where previously it could recognize faults up to 50% away from the transmission line, now the relay operates up to 45% and 33% in triphasic and single-phase faults respectively. Finally, when two generators are connected to the SEP, the impact that the relay has on its scope of protection is greater, because in the backup zone the protection covers up to 41% and 25% of the L/T in three-phase and single-phase faults. respectively. Due to the contribution of currently generated by the infeed effect, the relays sensitivity decreases under fault conditions. Consequently, this causes an underreach as the relay measures fault impedances at a greater distance from the actual location of the fault point. |
| eu_rights_str_mv | openAccess |
| format | bachelorThesis |
| id | UTC_ffbbd4db176925982a0c7142d19cafdc |
| identifier_str_mv | Padilla Choca Paola Jaqueline (2023); Evaluación del comportamiento de la protección de distancia (21) considerando el efecto Infeed en diferentes escenarios de operación. UTC. Latacunga. 85 p. PI-002620 |
| instacron_str | UTC |
| institution | UTC |
| instname_str | Universidad Técnica de Cotopaxi |
| language | spa |
| network_acronym_str | UTC |
| network_name_str | Repositorio Universidad Técnica de Cotopaxi |
| oai_identifier_str | oai:oai:repositorio.utc.edu.ec:27000:27000/11255 |
| publishDate | 2023 |
| publisher.none.fl_str_mv | Ecuador : Latacunga: Universidad Técnica de Cotopaxi (UTC) |
| reponame_str | Repositorio Universidad Técnica de Cotopaxi |
| repository.mail.fl_str_mv | . |
| repository.name.fl_str_mv | Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi |
| repository_id_str | 0 |
| rights_invalid_str_mv | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ |
| spelling | Evaluación del comportamiento de la protección de distancia (21) considerando el efecto Infeed en diferentes escenarios de operación.Padilla Choca, Paola JaquelineEFECTO INFEEDFALLASDISTANCIAS DE FALLASRELÉ DE DISTANCIAELECTRICIDADIn the present research project, the behavior of the distance protection (21) in the Santo Domingo – Baba and Baba – Quevedo transmission lines was analyzed, before the entry of the generators connected to the Baba bus, through the use of the DigSilent software Power Factory. The project included distance relays at the ends of the Santo Domingo – Baba and Baba – Quevedo transmission lines; the calibration of the protections was carried out without considering the generators connected to the Baba bar. Thus, when a generator enters the system, the protection presents problems to act in zone 2, because where previously it could recognize faults up to 50% away from the transmission line, now the relay operates up to 45% and 33% in triphasic and single-phase faults respectively. Finally, when two generators are connected to the SEP, the impact that the relay has on its scope of protection is greater, because in the backup zone the protection covers up to 41% and 25% of the L/T in three-phase and single-phase faults. respectively. Due to the contribution of currently generated by the infeed effect, the relays sensitivity decreases under fault conditions. Consequently, this causes an underreach as the relay measures fault impedances at a greater distance from the actual location of the fault point.En el presente proyecto de investigación se analizó el comportamiento de la protección de distancia (21) en las líneas de transmisión Santo Domingo – Baba y Baba – Quevedo, ante el ingreso de los generadores conectados a la barra Baba, mediante el uso del software DigSilent Power Factory. En el proyecto se incorporó relés de distancia en los extremos de las líneas de transmisión Santo Domingo – Baba y Baba – Quevedo; la calibración de las protecciones se realizó sin considerar los generadores conectados a la barra Baba. Es así, que cuando ingresa un generador al sistema, la protección presenta problemas para actuar en la zona 2, pues donde antes podía reconocer las fallas hasta el 50% de distancia de la línea de transmisión, ahora el relé opera hasta el 45% y 33% en fallas trifásicas y monofásicas respectivamente. Finalmente, cuando se conectan dos generadores al SEP, la afectación que tiene el relé en su alcance de protección es mayor, porque en la zona de respaldo la protección cubre hasta el 41% y 25% de la L/T en fallas trifásicas y monofásicas respectivamente. Debido a la aportación de corriente generado por el efecto infeed, la sensibilidad de los relés disminuye ante condiciones de fallas. En consecuencia, esto provoca un sub alcance pues el relé mide las impedancias de las fallas a una distancia mayor de la ubicación real del punto de falla.Ecuador : Latacunga: Universidad Técnica de Cotopaxi (UTC)Proaño Maldonado, Xavier Alfonso2023-09-28T16:22:54Z2023-09-28T16:22:54Z2023-08info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis85 páginasPadilla Choca Paola Jaqueline (2023); Evaluación del comportamiento de la protección de distancia (21) considerando el efecto Infeed en diferentes escenarios de operación. UTC. Latacunga. 85 p.PI-002620http://repositorio.utc.edu.ec/handle/27000/11255spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2023-09-29T08:01:38Zoai:oai:repositorio.utc.edu.ec:27000:27000/11255Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02025-01-26T03:46:01.401742Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue |
| spellingShingle | Evaluación del comportamiento de la protección de distancia (21) considerando el efecto Infeed en diferentes escenarios de operación. Padilla Choca, Paola Jaqueline EFECTO INFEED FALLAS DISTANCIAS DE FALLAS RELÉ DE DISTANCIA ELECTRICIDAD |
| status_str | publishedVersion |
| title | Evaluación del comportamiento de la protección de distancia (21) considerando el efecto Infeed en diferentes escenarios de operación. |
| title_full | Evaluación del comportamiento de la protección de distancia (21) considerando el efecto Infeed en diferentes escenarios de operación. |
| title_fullStr | Evaluación del comportamiento de la protección de distancia (21) considerando el efecto Infeed en diferentes escenarios de operación. |
| title_full_unstemmed | Evaluación del comportamiento de la protección de distancia (21) considerando el efecto Infeed en diferentes escenarios de operación. |
| title_short | Evaluación del comportamiento de la protección de distancia (21) considerando el efecto Infeed en diferentes escenarios de operación. |
| title_sort | Evaluación del comportamiento de la protección de distancia (21) considerando el efecto Infeed en diferentes escenarios de operación. |
| topic | EFECTO INFEED FALLAS DISTANCIAS DE FALLAS RELÉ DE DISTANCIA ELECTRICIDAD |
| url | http://repositorio.utc.edu.ec/handle/27000/11255 |