Determinación de arsénico en sedimento marino por espectrocopía atómica mediante su hidruro volátil generado electroquímicamente

In this study, the determination of arsenic in marine sediment of Bajo Alto Commune, Province of El Oro, Ecuador is described. The electrochemical generation of this volatile metallic hydride (arsine), was carried out using an amalgam cathode Au Hg gold mercury in a 0.5M H2SO4 solution. The results...

תיאור מלא

שמור ב:
מידע ביבליוגרפי
מחבר ראשי: Alvarado, José (author)
מחברים אחרים: Romero, Hugo (author), Fernández, Lenys (author), Caiminagua, Andrea (author)
פורמט: article
שפה:spa
יצא לאור: 2015
נושאים:
גישה מקוונת:http://repositorio.utmachala.edu.ec/handle/48000/5088
תגים: הוספת תג
אין תגיות, היה/י הראשונ/ה לתייג את הרשומה!
_version_ 1858387503246999552
author Alvarado, José
author2 Romero, Hugo
Fernández, Lenys
Caiminagua, Andrea
author2_role author
author
author
author_facet Alvarado, José
Romero, Hugo
Fernández, Lenys
Caiminagua, Andrea
author_role author
collection Repositorio Universidad Técnica de Machala
dc.creator.none.fl_str_mv Alvarado, José
Romero, Hugo
Fernández, Lenys
Caiminagua, Andrea
dc.date.none.fl_str_mv 2015
2016-06-27T19:11:18Z
2016-06-27T19:11:18Z
dc.format.none.fl_str_mv pp.12-15
application/pdf
dc.identifier.none.fl_str_mv Romero H., Fernández L., Caiminagua A. y Alvarado J. (2015) Determinación de arsénico en sedimento marino por espectrocopía atómica mediante su hidruro volátil generado electroquímicamente. CUMBRES, Revista Científica. 1(2) 12 - 15
1390-9541
http://repositorio.utmachala.edu.ec/handle/48000/5088
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Machala : Universidad Técnica de Machala
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Machala
instname:Universidad Técnica de Machala
instacron:UTMACH
dc.subject.none.fl_str_mv ESPECTROSCOPIA ATOMICA
GENERACION ELECTROQUIMICA
HIDRURO VOLATIL, ARSENICO
REVISTA CUMBRE
dc.title.none.fl_str_mv Determinación de arsénico en sedimento marino por espectrocopía atómica mediante su hidruro volátil generado electroquímicamente
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description In this study, the determination of arsenic in marine sediment of Bajo Alto Commune, Province of El Oro, Ecuador is described. The electrochemical generation of this volatile metallic hydride (arsine), was carried out using an amalgam cathode Au Hg gold mercury in a 0.5M H2SO4 solution. The results were compared with those obtained with other commonly used cathodes for generating this metal hydride. The results show that the marine sediments are not contaminated by arsenic. The concentration of mercury was 0.05 mg of kg, while the permitted limit according to the World Health Organization is 5mg of Kg. In addition, the cathode of Au, Hg has better tolerance to interference and repeatability of the cathodes of Au, Pt, Pb or reticulated glass carbon (RGC). The accuracy of the method was verified by determining As in a certified reference material.
eu_rights_str_mv openAccess
format article
id UTMACH_94cdcb1baebccdb94e3143fab2aa9cee
identifier_str_mv Romero H., Fernández L., Caiminagua A. y Alvarado J. (2015) Determinación de arsénico en sedimento marino por espectrocopía atómica mediante su hidruro volátil generado electroquímicamente. CUMBRES, Revista Científica. 1(2) 12 - 15
1390-9541
instacron_str UTMACH
institution UTMACH
instname_str Universidad Técnica de Machala
language spa
network_acronym_str UTMACH
network_name_str Repositorio Universidad Técnica de Machala
oai_identifier_str oai:repositorio.utmachala.edu.ec:48000/5088
publishDate 2015
publisher.none.fl_str_mv Machala : Universidad Técnica de Machala
reponame_str Repositorio Universidad Técnica de Machala
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Machala - Universidad Técnica de Machala
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Determinación de arsénico en sedimento marino por espectrocopía atómica mediante su hidruro volátil generado electroquímicamenteAlvarado, JoséRomero, HugoFernández, LenysCaiminagua, AndreaESPECTROSCOPIA ATOMICAGENERACION ELECTROQUIMICAHIDRURO VOLATIL, ARSENICOREVISTA CUMBREIn this study, the determination of arsenic in marine sediment of Bajo Alto Commune, Province of El Oro, Ecuador is described. The electrochemical generation of this volatile metallic hydride (arsine), was carried out using an amalgam cathode Au Hg gold mercury in a 0.5M H2SO4 solution. The results were compared with those obtained with other commonly used cathodes for generating this metal hydride. The results show that the marine sediments are not contaminated by arsenic. The concentration of mercury was 0.05 mg of kg, while the permitted limit according to the World Health Organization is 5mg of Kg. In addition, the cathode of Au, Hg has better tolerance to interference and repeatability of the cathodes of Au, Pt, Pb or reticulated glass carbon (RGC). The accuracy of the method was verified by determining As in a certified reference material.El presente estudio describe la determinación de arsénico en sedimento marino de la Comuna de Bajo Alto, Provincia de El Oro, Ecuador. La generación electroquímica de este hidruro metálico volátil arsina utilizó como cátodo una amalgama Au,Hg oro, mercurio en una solución 0,5 M de H2SO4. Los resultados se compararon con los obtenidos con otros cátodos utilizados comúnmente para la generación de este hidruro metálico. Se muestra que los sedimentos marinos de la comuna de Bajo Alto no están contaminados por arsénico (As) ya que la concentración de este metal fue de 0.05mg/Kg, mientras que los límites permitidos de acuerdo a la Organización Mundial de la Salud son de 5mg/Kg. Adicionalmente, el cátodo de Au/Hg tiene mejor tolerancia a la interferencia y mejor repetitividad que los cátodos de Au, Pt, Pb o carbono vítreo reticulado (RGC). La exactitud del método fue verificada determinando As en un material de referencia certificado.Machala : Universidad Técnica de Machala2016-06-27T19:11:18Z2016-06-27T19:11:18Z2015info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlepp.12-15application/pdfRomero H., Fernández L., Caiminagua A. y Alvarado J. (2015) Determinación de arsénico en sedimento marino por espectrocopía atómica mediante su hidruro volátil generado electroquímicamente. CUMBRES, Revista Científica. 1(2) 12 - 151390-9541http://repositorio.utmachala.edu.ec/handle/48000/5088spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Machalainstname:Universidad Técnica de Machalainstacron:UTMACH2025-11-22T04:38:47Zoai:repositorio.utmachala.edu.ec:48000/5088Institucionalhttp://repositorio.utmachala.edu.ec/Universidad públicahttps://www.utmachala.edu.ec/http://repositorio.utmachala.edu.ec/oai.Ecuador...opendoar:02025-11-22T04:38:47Repositorio Universidad Técnica de Machala - Universidad Técnica de Machalafalse
spellingShingle Determinación de arsénico en sedimento marino por espectrocopía atómica mediante su hidruro volátil generado electroquímicamente
Alvarado, José
ESPECTROSCOPIA ATOMICA
GENERACION ELECTROQUIMICA
HIDRURO VOLATIL, ARSENICO
REVISTA CUMBRE
status_str publishedVersion
title Determinación de arsénico en sedimento marino por espectrocopía atómica mediante su hidruro volátil generado electroquímicamente
title_full Determinación de arsénico en sedimento marino por espectrocopía atómica mediante su hidruro volátil generado electroquímicamente
title_fullStr Determinación de arsénico en sedimento marino por espectrocopía atómica mediante su hidruro volátil generado electroquímicamente
title_full_unstemmed Determinación de arsénico en sedimento marino por espectrocopía atómica mediante su hidruro volátil generado electroquímicamente
title_short Determinación de arsénico en sedimento marino por espectrocopía atómica mediante su hidruro volátil generado electroquímicamente
title_sort Determinación de arsénico en sedimento marino por espectrocopía atómica mediante su hidruro volátil generado electroquímicamente
topic ESPECTROSCOPIA ATOMICA
GENERACION ELECTROQUIMICA
HIDRURO VOLATIL, ARSENICO
REVISTA CUMBRE
url http://repositorio.utmachala.edu.ec/handle/48000/5088