Power Performance Verification of a Wind Turbine by using the Wilcoxon Signed-Rank Test

In this letter, nonparametric statistical inference is applied to designing a simple, inexpensive method of verifying the power performance of a wind turbine. The proposed method uses the data collected by the Supervisory Control and Data Acquisition (SCADA) system and the guaranteed power curve of...

Deskribapen osoa

Gorde:
Xehetasun bibliografikoak
Egile nagusia: Hernández Perdomo, W. (author)
Beste egile batzuk: Maldonado Correa, J. (author)
Formatua: article
Argitaratua: 2016
Gaiak:
Sarrera elektronikoa:http://dspace.utpl.edu.ec/handle/123456789/18730
Etiketak: Etiketa erantsi
Etiketarik gabe, Izan zaitez lehena erregistro honi etiketa jartzen!
Deskribapena
Gaia:In this letter, nonparametric statistical inference is applied to designing a simple, inexpensive method of verifying the power performance of a wind turbine. The proposed method uses the data collected by the Supervisory Control and Data Acquisition (SCADA) system and the guaranteed power curve of the turbine, and it says whether the power performance of a wind turbine differed significantly from what would be expected.