Design and Implementation of a Wastewater Heat Recovery System Prototype for Electric Showers in Quito-Ecuador
A wastewater heat recovery system was designed and implemented in the city of Quito - Ecuador. The prototype consists of adapting a heat exchanger to recover energy from wastewater and preheat the water that enters an electric shower. A temperature control system was designed and adapted to work bas...